Bryant Air Conditoner 533A User Manual

AIR CONDITIONER  
with Puron®  
533A (60 Hz)  
Sizes 024 thru 060  
WIDE RANGE OF SIZES—Available in 6 nominal sizes from  
024 through 060 to meet the needs of residential and light  
commercial applications.  
COMPRESSOR—This unit features a scroll compressor,  
which is significantly more efficient than conventional com-  
pressors. Its simple design offers improved reliability and  
each compressor is mounted on rubber isolators for addi-  
tional sound reduction. Scroll compressors start under most  
system loads, minimizing the need for start assistance com-  
ponents. For improved serviceability, all models are  
equipped with a compressor terminal plug. Continuous oper-  
ation is approved down to 55°F (12.8°C) in the cooling mode.  
(See cooling performance tables.) Operation down to 0°F or  
–20°F is approved when low-ambient requirements are met.  
WEATHER-PROTECTIVE CABINET—The access panels  
and top are protected with a galvanized coating, then treated  
with a layer of zinc phosphate to which a modified polyester  
powder coating is applied and baked on. This provides each  
unit with a hard, smooth finish that will last for many years.  
All screws on cabinet exterior are coated for a long-lasting,  
rust-resistant, quality appearance.  
TOTALLY ENCLOSED FAN MOTOR—Means greater reli-  
ability under adverse weather conditions and dependable  
performance for many years. The permanent-split-capacitor  
type motor was designed for optimum efficiency. The motor  
was tested and qualified under extreme conditions to ensure  
the greatest reliability.  
Model 533A Energy-Efficient Air Conditioners incorporate  
innovative technology to provide quiet, reliable cooling per-  
formance. Built into these units are the features most desired  
by homeowners today including SEER ratings of at least  
12.0 when combined with specific Bryant equipment. The  
533A air conditioning system has been designed utilizing  
Bryant’s Puron® refrigerant. The environmentally sound  
refrigerant allows you to make a responsible decision in the  
protection of the earth’s ozone layer. All models are listed  
with UL, c-UL, ARI, CEC, and CSA-EEV. The 533A meets  
the Energy Star® guidelines for energy efficiency.  
APPLICATION VERSATILITY—The 533A can be combined  
with a wide variety of evaporator coils and blower packages  
to provide quiet, dependable comfort. Unit can be installed  
on a roof or at ground level on a slab.  
EXTERNAL SERVICE VALVES—Both service valves are  
brass, front seating type with sweat connections. Valves are  
externally located so refrigerant tube connections can be  
made quickly and easily. Each valve has a service port for  
ease of checking operating refrigerant pressures.  
AVAILABLE OPTIONS  
Puron® Environmentally Friendly Refrigerant—Is Bryant’s  
refrigerant designed to help protect the environment. Puron®  
is an HFC refrigerant that does not contain chlorine, which is  
damaging to the ozone layer. The most important advantage  
of Puron® refrigerant is that it has not been banned in future  
air conditioning systems as the traditional refrigerant, R-22,  
has been. Puron® refrigerant is in service in thousands of  
systems providing highly reliable, environmentally sound  
performance. For specific R-22 phase out information see  
your Bryant distributor.  
EASY SERVICEABILITY—One access panel provides  
access to electrical controls and compressor. Removal of  
wire dome gives access to fan motor and removal of the top  
gives access to the coil.  
COMPRESSOR PROTECTION—All compressors are pro-  
tected by internal temperature and current sensitive over-  
loads. An internal pressure relief is provided for high-  
pressure protection to the refrigerant system.  
Long term reliability is assured through the use of both high  
and low pressure switches. Also included is a liquid line filter  
drier designed to trap moisture and contaminants, which  
could otherwise shorten the life of the system.  
UNIT DESIGN—Copper tube, enhanced sine wave alumi-  
num fin coil is designed for optimum heat transfer. Vertical air  
discharge carries sound and hot condenser air up and away  
from adjacent patio areas and foliage. Heat pump style base  
pan for easy removal of water, dirt, and leaves.  
LIMITED WARRANTY—Standard 1-year warranty on all  
parts. Additional 4-year warranty on compressor.  
ELECTRICAL RANGE—All units are offered in single  
phase 208/230v. The 030 through 060 sizes are offered in  
208/230v 3 phase.  
Form No. PDS 533A.24.1  
RECOMMENDED TUBE DIAMETERS  
Liquid Tube Diameter (In.)  
Vapor Tube Diameter (In.)  
UNIT  
SIZE  
0 to 50 Ft  
Tube Length  
0 to 50 Ft  
Tube Length  
Long-Line Applications*  
(Maximum Diameter)  
Long-Line Applications*  
024  
5/8  
3/4  
3/4  
7/8  
030, 036  
042, 048  
060  
3/8  
3/8  
7/8  
1-1/8  
1-1/8  
1-1/8  
* For tube sets greater than 50 ft, consult Residential Split System Application Guideline and Service Manual.  
CHECK-FLO-RATER® PISTON  
PISTON*  
IDENTIFICATION NO.  
UNIT SIZE–SERIES  
024-A  
61  
63  
70  
76  
76  
90  
030-A  
036-A  
042-A  
048-A  
060-A  
* Piston listed is for any approved non-capillary tube coil combination. Piston is shipped  
with outdoor unit and must be installed in an approved indoor coil.  
CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE*)  
UNIT SIZE–SERIES  
024-A  
REQUIRED SUBCOOLING (°F)  
10  
15  
12  
15  
15  
15  
030-A  
036-A  
042-A  
048-A  
060-A  
* Must be a Puron® approved hard shutoff TXV.  
®
As an ENERGY STAR  
partner, Bryant Heating &  
Cooling Systems has  
determined that this prod-  
uct meets the ENERGY  
®
STAR guidelines for  
energy efficiency.  
P
CERTIFICATION APPLIES ONLY  
WHEN THE COMPLETE SYSTEM  
IS LISTED WITH ARI.  
REGISTERED QUALITY SYSTEM  
—3—  
SPECIFICATIONS  
UNIT SIZE-SERIES  
024-A  
030-A/A  
036-A/A  
Operating Weight (Lb)  
143  
138  
156  
ELECTRICAL  
Unit Volts—Hertz—Phase  
208/230—60—1  
208/230—60—1/208/230—60—3  
208/230—60—1/208/230—60—3  
Operating Voltage Range*  
187—253  
13.5  
61.0  
0.50  
17.4  
14  
187—253/197—253  
14.7/9.6  
72.5/63.0  
0.80  
187—253/197—253  
15.4/12.2  
83.0/77.0  
1.4  
Compressor— Rated Load Amps  
Locked Rotor Amps  
Condenser Fan Motor—Full Load Amps  
Min Unit Ampacity for Wire Sizing  
Min Wire Size (60°C Copper) AWG†  
Min Wire Size (75°C Copper) AWG†  
Max Wire Length (Ft) (60°C Copper)‡  
Max Wire Length (Ft) (75°C Copper)‡  
19.2/12.8  
14  
20.7/16.7  
12/14  
14  
14  
12/14  
45  
41/70  
62/54  
43  
39/67  
59/51  
Max Branch Circuit Fuse or  
Circuit Breaker Size (Amps)  
25  
30/20  
30/25  
COMPRESSOR & REFRIGERANT  
CompressorType  
Scroll  
Copeland  
Manufacturer  
Temperature & Current Protection  
Refrigerant— Type  
Internal Line Break  
Puron® (R-410A)  
5.50  
Amount (Lb)  
5.00  
5.75  
CONDENSER COIL & FAN  
Coil Face Area (Sq Ft)  
Fins per In.—Rows—Circuits  
Fan Motor—HP (PSC) & RPM  
Volts—Hertz—Phase  
Condenser Airflow (CFM)  
OPTIONAL EQUIPMENT  
Support Feet  
11.59  
10.77  
25—1—2  
12.42  
25—1—2  
1/12 & 1100  
25—1—2  
1/4 & 1100  
1/10 & 1100  
208/230—60—1  
2400  
1800  
2400  
KSASF0101AAA  
KAACF1001MED  
KAATD0101TDR  
KSACY0101AAA  
KAACH1201AAA  
Coastal Filter  
Time Delay Relay  
Cycle Protector  
Crankcase Heater  
Sound Blanket  
KSASH1801COP  
KSASH0601COP  
KSATX0301HSZ  
Start Assist—Capacitor/Relay Type  
Start Assist—PTC Type  
TXV (Hard Shutoff)  
KSAHS1501AAA/NA  
KAACS0201PTC/NA  
KSATX0201HSZ  
Piston Body  
KSAPX0101PIS  
KH45LG140 (RCD)  
KAAFT0101AAA  
KAALS0201LLS  
KAAWS0101AAA  
KSALA0301410  
P251-0083 (RCD)  
32LT660004 (RCD)  
Filter Drier (Suction Line)  
Evaporator Freeze Thermostat††  
Liquid-Line Solenoid Valve  
Winter Start Control††  
Low-Ambient Pressure Switch  
Low-Ambient Controller  
MotorMaster® Control**  
Ball Bearing Fan Motor  
HC34GE232(RCD)  
HC40GE232(RCD)  
Thermostat—Auto Changeover,  
Non-Programmable, °F/°C,  
1-Stage Heat, 1-Stage Cool  
TSTATBBNAC01-B  
Thermostat—Auto Changeover,  
7-Day Programmable, °F/°C,  
1-Stage Heat, 1-Stage Cool  
TSTATBBPAC01-B  
TSTATBBPRH01-B  
Thermidistat™ Control—  
Programmable Thermostat with Humidity Control  
Builder’s Thermostat—Manual Changeover,  
Non-Programmable, °F/°C,  
1-Stage Heat, 1-Stage Cool  
TSTATBBBAC01-B  
Thermostat, Manual Changeover, 5-2 Day  
Programmable, °F/°C, 1-Stage heat/1-Stage Cool  
TSTATBBSAC01  
TSTATXXSEN01-B  
TSTATXXNBP01  
TSTATXXPBP01  
TSTATXXBBP01  
Outdoor Air Temperature Sensor  
Backplate for Non-Programmable Thermostat  
Backplate for Programmable Thermostat  
Backplate for Builder’s Thermostat  
Backplate for Standard Programmable  
Thermostat  
TSTATXXSBP01  
TSTATXXCNV10  
Thermostat Conversion Kit (4 to 5 wire)—10 Pack  
See notes on page 6.  
—4—  
SPECIFICATIONS Continued  
UNIT SIZE-SERIES  
042-A/A  
048-A/A  
060-A/A  
Operating Weight (Lb)  
197  
203  
238  
ELECTRICAL  
Unit Volts—Hertz—Phase  
208/230—60—1/208/230—60—3  
Operating Voltage Range*  
187—253/197—253  
20.5/14.7  
109.0/91.0  
1.4  
Compressor—Rated Load Amps  
Locked Rotor Amps  
18.6/13.5  
105.0/77.0  
1.1  
27.6/18.1  
158.0/137.0  
1.4  
Condenser Fan Motor—Full Load Amps  
Min Unit Ampacity for Wire Sizing  
Min Wire Size (60°C Copper) AWG†  
Min Wire Size (75°C Copper) AWG†  
Max Wire Length (Ft) (60°C Copper)‡  
Max Wire Length (Ft) (75°C Copper)‡  
24.4/18.0  
10/14  
27.0/19.8  
10/12  
35.9/24.0  
8/10  
10/14  
10/12  
8/10  
81/51  
74/73  
86/96  
77/48  
70/69  
82/91  
Max Branch Circuit Fuse or  
Circuit Breaker Size (Amps)  
40/25  
40/30  
60/40  
COMPRESSOR & REFRIGERANT  
CompressorType  
Scroll  
Copeland  
Manufacturer  
Temperature & Current Protection  
Refrigerant—Type  
Internal Line Break  
Puron® (R-410A)  
7.13  
Amount (Lb)  
6.38  
9.75  
CONDENSER COIL & FAN  
Coil Face Area (Sq Ft)  
Fins per In.—Rows—Circuits  
Fan Motor—HP (PSC) & RPM  
Volts—Hertz—Phase  
Condenser Airflow (CFM)  
OPTIONAL EQUIPMENT  
Support Feet  
14.8  
14.8  
25—1—2  
1/4 & 1100  
208/230—60—1  
2800  
22.2  
20—1—2  
1/5 & 825  
25—1—3  
1/4 & 1100  
2800  
3300  
KSASF0101AAA  
KAACF1101LRG  
KAATD0101TDR  
KSACY0101AAA  
KAACH1201AAA  
Coastal Filter  
Time Delay Relay  
Cycle Protector  
Crankcase Heater  
Sound Blanket  
KSASH0601COP  
KSASH2101COP  
Start Assist—Capacitor/Relay Type  
Start Assist—PTC Type  
TXV (Hard Shutoff)  
KSAHS1501AAA/NA  
KSAHS1601AAA/NA  
KAACS0201PTC/NA  
KSATX0401HSZ  
KSATX0301HSZ  
KSATX0501HSZ  
Piston Body  
KSAPX0101PIS  
Filter Drier (Suction Line)  
Evaporator Freeze Thermostat††  
Liquid-Line Solenoid Valve  
Winter Start Control††  
Low-Ambient Pressure Switch  
Low-Ambient Controller  
MotorMaster® Control**  
Ball Bearing Fan Motor  
KH45LG141 (RCD)  
KAAFT0101AAA  
KAALS0201LLS  
KAAWS0101AAA  
KSALA0301410  
P251-0083 (RCD)  
32LT660004 (RCD)  
HC38GE231 (RCD)  
Thermostat—Auto Changeover,  
Non-Programmable, °F/°C,  
1-Stage Heat, 1-Stage Cool  
TSTATBBNAC01-B  
Thermostat—Auto Changeover,  
7-Day Programmable, °F/°C,  
1-Stage Heat, 1-Stage Cool  
TSTATBBPAC01-B  
TSTATBBPRH01-B  
Thermidistat™ Control—  
Programmable Thermostat with Humidity Control  
Builder’s Thermostat—Manual Changeover,  
Non-Programmable, °F/°C,  
1-Stage Heat, 1-Stage Cool  
TSTATBBBAC01-B  
Thermostat, Manual Changeover, 5-2 Day  
Programmable, °F/°C, 1-Stage heat/1-Stage Cool  
TSTATBBSAC01  
TSTATXXSEN01-B  
TSTATXXNBP01  
TSTATXXPBP01  
TSTATXXBBP01  
Outdoor Air Temperature Sensor  
Backplate for Non-Programmable Thermostat  
Backplate for Programmable Thermostat  
Backplate for Builder’s Thermostat  
Backplate for Standard Programmable  
Thermostat  
TSTATXXSBP01  
TSTATXXCNV10  
Thermostat Conversion Kit (4 to 5 wire)—10 Pack  
See notes on page 6.  
—5—  
* Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure.  
† If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70).  
The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26. If  
other than uncoated (non-plated), 60 or 75°C (140 or 167°F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is  
used, consult applicable tables of the NEC (ANSI/NFPA 70).  
‡ Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%.  
** Fan motor with ball bearings required.  
†† See low-ambient controller Installation Instructions for application.  
N/A — Not Applicable.  
NOTE: Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection.  
ACCESSORY USAGE GUIDELINE  
REQUIRED FOR  
LOW-AMBIENT  
APPLICATIONS  
(Below 55°F)  
REQUIRED FOR  
LONG-LINE  
APPLICATIONS*  
(Over 50 Ft)  
REQUIRED FOR  
SEA COAST  
APPLICATIONS  
(Within 2 Miles)  
ACCESSORY  
Crankcase Heater  
Yes  
Yes  
Yes†  
No  
Yes  
No  
No  
No  
No  
No  
No  
No  
Evaporator Freeze Thermostat  
Winter Start Control  
Accumulator  
Compressor Start Assist  
Capacitor and Relay  
Yes  
Yes  
No  
Low-Ambient Controller,  
MotorMaster® Control,  
or  
Yes  
No  
No  
Low-Ambient Pressure Switch  
Wind Baffle  
Coastal Filter  
Support Feet  
See Low-Ambient Instructions  
No  
No  
No  
No  
Yes  
No  
Recommended  
Recommended  
Liquid-Line Solenoid Valve  
See Long-Line  
Application  
Guideline  
or  
No  
No  
No  
Hard Shutoff TXV  
Ball Bearing Fan Motor  
Yes‡  
No  
* For tubing line sets greater than 50 ft, refer to Residential Split-System Long-Line Application Guideline and Service Manual.  
† Only when low-pressure switch is used.  
‡ Required for Low-Ambient Controller (full modulation feature) and MotorMaster® Control only.  
ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically)  
1. Ball Bearing Fan Motor  
A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.  
SUGGESTED USE: Required on all units where Low-Ambient Controller (full modulation feature) or MotorMaster® Control has been added.  
2. Coastal Filter  
A mesh screen inserted under the top cover and inside base pan to protect the condenser coil from corrosive atmosphere without restricting airflow.  
SUGGESTED USE: In geographic areas where salt damage could occur.  
In areas with high pollution levels.  
3. Compressor Start Assist—Capacitor/Relay Type  
Start capacitor and start relay which gives a “hard” boost to compressor motor at each start-up.  
SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft.  
Installations where outdoor design temperature exceeds 105°F (40.6°C).  
Installations where Liquid-Line Solenoid Valve or hard shutoff TXV has been added.  
4. Compressor Start Assist—PTC Type  
Solid-state electrical device which gives a “soft” boost to compressor motor at each start-up.  
SUGGESTED USE: Installations with marginal power supply.  
5. Crankcase Heater  
An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication  
on restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control.  
SUGGESTED USE: When interconnecting tube length exceeds 50 ft.  
When unit will be operated below 55°F (12.8°C) outdoor air temperature. Use with Low-Ambient Controller.  
All commercial installations.  
6. Cycle Protector  
Solid state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor has  
been interrupted for any reason, including normal room thermostat cycling.  
SUGGESTED USE: Installations in areas where power interruptions are frequent.  
Where user is likely to “play” with the room thermostat.  
All commercial installations.  
Installations where interconnecting tube length exceeds 50 ft.  
High-rise applications.  
7. Evaporator Freeze Thermostat  
An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions.  
SUGGESTED USE: All units where Winter Start Control has been added.  
8. Filter Drier (Suction Line)  
A device for removing contaminants from refrigerant circulating in an air conditioner: 1-direction flow.  
SUGGESTED USE: All split-system air conditioners.  
—6—  
ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) Continued  
9. Liquid-Line Solenoid Valve (LSV)  
An electrically operated shutoff valve to be installed at the outdoor or indoor unit (depending on tubing configuration) and which stops and starts refrigerant  
liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle.  
NOTE: Compressor Start Assist—Capacitor/Relay Type must also be used. Do not use with hard shutoff TXV.  
SUGGESTED USE: For improved system performance in air conditioners for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.  
In certain long-line applications. Refer to Residential Split System Long-Line Application Guideline and Service Manual.  
10. Low-Ambient Controller  
Head pressure controller is a cycle control device activated by a temperature sensor mounted on a header tube of the outdoor coil. It is designed to cycle  
the outdoor fan motor in order to maintain condensing temperature within normal operating limits (approximately100°F/37.8°C high and 60°F/15.5°C low).  
The control will maintain working head pressure at low-ambient temperatures down to 0°F(–17.8°C) when properly installed.  
SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F (12.8°C).  
11. Low-Ambient Pressure Switch  
A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure  
within normal operating limits (approximately 200 psig to 365 psig). The control will maintain working head pressure at low-ambient temperatures down to  
0°F (–17.8°C) when properly installed.  
SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F (12.8°C).  
12. MotorMaster® Control  
A fan speed control device activated by a temperature sensor. Designed to control condenser fan motor speed in response to the saturated, condensing  
temperature during operation in cooling mode only. For outdoor temperatures down to –20°F (–28.9°C), it maintains condensing temperature at  
100°F ± 10°F (37.8°C ± 5.6°C).  
SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F (12.8°C).  
All commercial installations.  
13. Outdoor Air Temperature Sensor  
A device that allows the temperature at a remote location (outdoors) to be displayed at the thermostat.  
SUGGESTED USE: All Bryant programmable thermostats.  
14. Piston Body  
This piston body is to be used as a replacement for the FK4C Fan Coil R-22 thermostatic expansion valve when used with Puron® (R-410A) air conditioner  
units. Use piston and piston ring shipped with outdoor unit for installations under 50 ft.  
SUGGESTED USE: All Puron® air conditioner installations matched with FK4C Fan Coils.  
15. Support Feet  
Four stick-on plastic feet which raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base,  
minimizing corrosion.  
SUGGESTED USE: For improved sound ratings.  
Coastal installations.  
Windy areas or where debris is normally circulating.  
Rooftop installations.  
16. Thermostatic Expansion Valve (TXV)  
A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the  
evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Hard shutoff valves are available. Do not use with Liquid-Line Solenoid Valve.  
NOTE: Compressor Start Assist—Capacitor/Relay Type must also be used. Do not use with Liquid Line Solenoid.  
SUGGESTED USE: For improved system performance in cooling mode for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.  
Required for use on all zoning systems.  
17. Time-Delay Relay  
An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off.  
SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.  
Required for use on all zoning systems.  
18. Winter Start Control  
An SPST delay relay which bypasses the low-pressure switch for approximately 3 minutes to permit start-up for cooling operation under low-load  
conditions.  
SUGGESTED USE: All air conditioners where Low-Ambient Controller has been added.  
SOUND POWER (dBA)  
OCTAVE BAND CENTER FREQUENCY (Hz)  
UNIT  
SIZE  
024  
030  
036  
042  
048  
060  
125  
49.0  
49.5  
57.5  
54.0  
57.0  
70.5  
250  
58.5  
62.5  
63.5  
67.5  
70.5  
72.5  
500  
65.0  
68.5  
68.0  
68.5  
73.5  
72.5  
1000  
72.0  
72.5  
75.0  
72.5  
75.5  
75.0  
2000  
66.4  
67.5  
71.0  
71.5  
73.0  
69.5  
4000  
62.0  
62.5  
65.5  
64.0  
69.5  
65.5  
8000  
57.5  
56.0  
58.5  
60.0  
64.0  
61.5  
Not listed in ARI; however, tested in accordance with ARI Standard 270-95.  
SOUND POWER (dBA)  
UNIT SIZE  
024  
W/SOUND BLANKET  
W/O SOUND BLANKET  
74  
75  
76  
77  
78  
78  
76  
77  
79  
79  
80  
80  
030  
036  
042  
048  
060  
—7—  
COMBINATION RATINGS  
SEER  
FACTORY-  
Bryant Gas  
Furnace or  
Accessory  
TDR†  
TOT.  
CAP.  
BTUH  
SUPPLIED  
ENHANCE-  
MENT  
UNIT  
SIZE-SERIES  
INDOOR  
MODEL  
Standard  
Rating  
Accessory  
TXV‡  
EER  
CK5A/CK5BA030*  
CC5A/CD5AA024  
CC5A/CD5AA030  
CC5A/CD5AW024  
CC5A/CD5AW030  
CE3AA024  
23,000  
23,000  
23,000  
23,000  
23,000  
23,000  
23,000  
23,000  
23,000  
23,000  
23,000  
23,000  
23,000  
23,200  
23,600  
23,200  
23,600  
23,000  
23,600  
22,800  
23,400  
23,600  
23,600  
23,600  
23,600  
23,600  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
TDR  
12.00  
11.70  
12.00  
11.70  
12.00  
11.70  
12.00  
11.70  
11.70  
12.00  
11.70  
11.70  
12.00  
12.00  
11.70  
12.00  
11.70  
12.00  
11.70  
12.00  
11.70  
11.70  
12.00  
11.70  
11.70  
12.00  
12.00  
12.20  
10.05  
9.90  
9.95  
9.90  
9.95  
10.00  
10.10  
9.95  
CE3AA030  
CF5AA024  
CK3BA024  
10.05  
10.05  
10.05  
10.05  
10.05  
10.10  
10.20  
10.05  
10.15  
9.95  
CK3BA030  
CK5A/CK5BA024  
CK5A/CK5BW024  
CK5A/CK5BW030  
F(A,B)4AN(F,C)024  
F(A,B)4AN(F,C)030  
FC4BNF024  
12.00  
12.20  
12.00  
12.20  
11.70  
12.00  
TDR  
TDR&TXV  
TDR&TXV  
TDR  
FC4BNF030  
FF1(B,C,D)NA024  
FF1(B,C,D)NA030  
FG3AAA024  
11.70  
12.00  
11.70  
13.50  
13.70  
12.20  
TDR  
10.10  
9.80  
NONE  
TDR&TXV  
TDR&TXV  
TDR&TXV  
NONE  
NONE  
NONE  
11.70  
FK4CNF001  
13.00  
13.50  
13.50  
13.50  
13.70  
12.20  
11.05  
11.10  
11.30  
11.10  
11.30  
10.25  
FK4CNF002  
FK4CNF003  
FV4ANF002  
FV4ANF003  
FX4ANF030  
024-A  
COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE  
CC5A/CD5AA024  
CC5A/CD5AA030  
CC5A/CD5AW030  
CK3BA024  
23,000  
23,600  
23,600  
23,000  
23,200  
23,000  
23,600  
23,600  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
12.50  
13.00  
13.00  
12.50  
13.00  
12.50  
13.00  
13.00  
12.50  
13.00  
13.00  
12.50  
13.00  
12.50  
13.00  
13.00  
10.65  
10.80  
10.80  
10.85  
10.95  
10.85  
10.95  
10.95  
CK3BA030  
CK5A/CK5BA024  
CK5A/CK5BA030  
CK5A/CK5BW030  
COILS + 355MAV042040 VARIABLE SPEED FURNACE  
CC5A/CD5AW030  
CK5A/CK5BW030  
23,200  
23,200  
TDR  
TDR  
13.00  
13.00  
13.00  
13.00  
10.75  
10.80  
COILS + 355MAV042060 VARIABLE SPEED FURNACE  
CC5A/CD5AW024  
CC5A/CD5AW030  
CK3BA024  
23,000  
23,200  
23,000  
23,200  
23,000  
23,200  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
12.50  
13.00  
12.50  
13.00  
12.50  
13.00  
12.50  
13.00  
12.50  
13.00  
12.50  
13.00  
10.60  
10.75  
10.75  
10.80  
10.75  
10.80  
CK3BA030  
CK5A/CK5BW024  
CK5A/CK5BW030  
COILS + 355MAV042080 VARIABLE SPEED FURNACE  
CC5A/CD5AW024  
CC5A/CD5AW030  
CK5A/CK5BW024  
CK5A/CK5BW030  
23,000  
23,200  
23,000  
23,200  
TDR  
TDR  
TDR  
TDR  
12.50  
13.00  
12.50  
13.00  
12.50  
13.00  
12.50  
13.00  
10.80  
10.95  
10.95  
11.00  
CK5A/CK5BA036*  
CC5A/CD5AA030  
CC5A/CD5AA036  
CC5A/CD5AW030  
CC5A/CD5AW036  
CE3AA030  
29,000  
28,000  
29,000  
28,000  
29,000  
28,000  
28,200  
28,800  
28,000  
29,000  
28,000  
28,000  
29,000  
28,000  
29,000  
27,800  
28,000  
27,800  
28,000  
28,400  
28,400  
28,000  
28,400  
28,400  
29,200  
28,400  
28,800  
29,200  
27,800  
28,000  
NONE  
NONE  
12.00  
11.70  
12.00  
11.70  
12.00  
11.70  
12.00  
12.00  
11.70  
12.00  
11.70  
11.70  
12.00  
11.70  
12.00  
12.00  
11.70  
12.00  
11.70  
12.00  
11.70  
12.00  
12.00  
11.70  
12.00  
11.70  
11.70  
12.00  
11.70  
12.00  
11.70  
11.70  
10.45  
10.10  
10.40  
10.10  
10.40  
10.25  
10.30  
10.40  
10.15  
10.45  
10.15  
10.45  
10.45  
10.15  
10.45  
10.30  
10.20  
10.25  
10.10  
10.15  
10.25  
11.10  
11.20  
11.55  
11.85  
11.25  
11.55  
11.85  
10.40  
10.20  
NONE  
NONE  
NONE  
NONE  
CE3AA036  
NONE  
CF5AA036  
NONE  
CK3BA030  
NONE  
CK3BA036  
NONE  
CK5A/CK5BA030  
CK5A/CK5BN036  
CK5A/CK5BT036  
CK5A/CK5BW030  
CK5A/CK5BW036  
F(A,B)4AN(F,C)030  
F(A,B)4AN(F,C)036  
FC4BNF030  
NONE  
NONE  
NONE  
NONE  
NONE  
030-A  
TDR  
11.70  
11.70  
11.70  
11.70  
11.70  
11.70  
13.00  
13.00  
13.50  
14.00  
13.20  
13.70  
14.00  
12.00  
11.70  
TDR  
TDR&TXV  
TDR&TXV  
TDR  
FC4BNF036  
FF1(B,C,D)NA030  
FG3AAA036  
11.70  
11.70  
NONE  
FK4CNF001  
TDR&TXV  
TDR&TXV  
TDR&TXV  
TDR&TXV  
NONE  
FK4CNF002  
FK4CNF003  
FK4CNF005  
FV4ANF002  
13.20  
13.70  
14.00  
12.00  
11.70  
FV4ANF003  
NONE  
FV4ANF005  
NONE  
FX4ANF030  
NONE  
FX4ANF036  
NONE  
See notes on page 13.  
—8—  
COMBINATION RATINGS Continued  
SEER  
FACTORY-  
SUPPLIED  
ENHANCE-  
MENT  
Bryant Gas  
Furnace or  
Accessory  
TDR†  
TOT.  
CAP.  
BTUH  
UNIT  
SIZE-SERIES  
INDOOR  
MODEL  
Standard  
Rating  
Accessory  
TXV‡  
EER  
COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE  
CC5A/CD5AA030  
CC5A/CD5AA036  
CC5A/CD5AW030  
CK3BA030  
27,800  
29,000  
27,800  
27,800  
29,000  
27,800  
29,000  
27,800  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
12.50  
13.00  
12.50  
12.50  
13.00  
12.50  
13.00  
12.50  
12.50  
13.00  
12.50  
12.50  
13.00  
12.50  
13.00  
12.50  
10.80  
11.25  
10.80  
10.90  
11.30  
10.90  
11.30  
10.90  
CK3BA036  
CK5A/CK5BA030  
CK5A/CK5BA036  
CK5A/CK5BW030  
COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE  
CC5A/CD5AW030  
CC5A/CD5AW036  
CK5A/CK5BW030  
CK5A/CK5BW036  
27,800  
29,000  
27,800  
29,000  
TDR  
TDR  
TDR  
TDR  
12.50  
13.00  
12.50  
13.00  
12.50  
13.00  
12.50  
13.00  
11.00  
11.45  
11.05  
11.50  
COILS + 355MAV042040 VARIABLE SPEED FURNACE  
CC5A/CD5AW030  
CC5A/CD5AW036  
CK5A/CK5BW030  
CK5A/CK5BW036  
28,000  
29,000  
28,000  
29,000  
TDR  
TDR  
TDR  
TDR  
12.30  
13.00  
12.30  
13.00  
12.30  
13.00  
12.30  
13.00  
10.60  
11.05  
10.65  
11.10  
COILS + 355MAV042060 VARIABLE SPEED FURNACE  
CC5A/CD5AA036  
CC5A/CD5AW030  
CK3BA030  
29,000  
28,000  
28,000  
29,000  
29,000  
28,000  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
12.70  
12.30  
12.30  
13.00  
13.00  
12.30  
12.70  
12.30  
12.30  
13.00  
13.00  
12.30  
11.05  
10.60  
10.65  
11.10  
11.10  
10.65  
030-A  
CK3BA036  
CK5A/CK5BA036  
CK5A/CK5BW030  
COILS + 355MAV042080 VARIABLE SPEED FURNACE  
CC5A/CD5AW030  
CC5A/CD5AW036  
CK5A/CK5BW030  
CK5A/CK5BW036  
28,000  
29,000  
28,000  
29,000  
TDR  
TDR  
TDR  
TDR  
12.50  
13.00  
12.50  
13.00  
12.50  
13.00  
12.50  
13.00  
10.70  
11.15  
10.75  
11.20  
COILS + 355MAV060080 VARIABLE SPEED FURNACE  
CC5A/CD5AW030  
CC5A/CD5AW036  
CK5A/CK5BW030  
CK5A/CK5BW036  
28,000  
29,000  
28,000  
29,000  
TDR  
TDR  
TDR  
TDR  
12.30  
12.70  
12.30  
13.00  
12.30  
12.70  
12.30  
13.00  
10.55  
11.05  
10.60  
11.05  
COILS + 355MAV060100 VARIABLE SPEED FURNACE  
CC5A/CD5AW030  
CC5A/CD5AW036  
CK5A/CK5BW030  
CK5A/CK5BW036  
28,000  
29,000  
28,000  
29,000  
TDR  
TDR  
TDR  
TDR  
12.50  
13.00  
12.50  
13.00  
12.50  
13.00  
12.50  
13.00  
10.95  
11.40  
11.00  
11.40  
COILS + 355MAV060120 VARIABLE SPEED FURNACE  
CC5A/CD5AW036  
CK5A/CK5BW036  
29,000  
29,000  
TDR  
TDR  
13.00  
13.00  
13.00  
13.00  
11.35  
11.35  
CK5A/CK5BA042*  
CC5A/CD5AA036  
CC5A/CD5AA042  
CC5A/CD5AW036  
CC5A/CD5AW042  
CE3AA036  
35,000  
35,000  
35,000  
35,000  
34,800  
34,600  
35,000  
34,800  
35,000  
35,000  
35,000  
35,000  
35,000  
35,000  
35,000  
35,000  
34,000  
35,000  
34,000  
34,000  
35,400  
33,800  
34,000  
34,200  
35,000  
35,800  
34,000  
34,200  
35,000  
34,000  
NONE  
NONE  
12.00  
12.00  
12.00  
12.00  
12.00  
11.70  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
11.70  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
11.50  
10.40  
10.40  
10.40  
10.40  
10.30  
10.25  
10.45  
10.35  
10.40  
10.40  
10.40  
10.40  
10.40  
10.40  
10.40  
10.35  
10.10  
10.30  
10.05  
10.20  
12.00  
10.80  
10.85  
11.30  
11.75  
12.00  
10.85  
11.30  
11.75  
10.45  
NONE  
NONE  
NONE  
NONE  
CE3AA042  
NONE  
CF5AA036  
NONE  
CK3BA036  
NONE  
CK3BA042  
NONE  
CK5A/CK5BA036  
CK5A/CK5BN042  
CK5A/CK5BT036  
CK5A/CK5BT042  
CK5A/CK5BW036  
F(A,B)4AN(F,B,C)042  
F(A,B)4AN(F,C)036  
FC4BN(F,B)042  
FC4BNF036  
NONE  
NONE  
NONE  
NONE  
NONE  
TDR  
12.00  
11.50  
12.00  
11.50  
TDR  
036-A  
TDR&TXV  
TDR&TXV  
NONE  
FG3AAA036  
11.50  
11.50  
FK4CNB006  
TDR&TXV  
TDR&TXV  
TDR&TXV  
TDR&TXV  
TDR&TXV  
NONE  
14.00  
12.50  
12.50  
13.00  
13.50  
14.00  
12.50  
13.00  
13.70  
12.10  
FK4CNF001  
FK4CNF002  
FK4CNF003  
FK4CNF005  
FV4ANB006  
14.00  
12.50  
13.00  
13.70  
12.10  
FV4ANF002  
NONE  
FV4ANF003  
NONE  
FV4ANF005  
NONE  
FX4ANF042  
NONE  
COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE  
CC5A/CD5AA036  
CK3BA036  
CK5A/CK5BA036  
34,600  
34,600  
34,600  
TDR  
TDR  
TDR  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
10.90  
10.95  
10.95  
See notes on page 13.  
—9—  
COMBINATION RATINGS Continued  
SEER  
FACTORY-  
SUPPLIED  
ENHANCE-  
MENT  
Bryant Gas  
Furnace or  
Accessory  
TDR†  
TOT.  
CAP.  
BTUH  
UNIT  
SIZE-SERIES  
INDOOR  
MODEL  
Standard  
Rating  
Accessory  
TXV‡  
EER  
COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE  
CC5A/CD5AA042  
CC5A/CD5AW036  
CC5A/CD5AW042  
CK3BA042  
CK5A/CK5BA042  
CK5A/CK5BW036  
34,600  
34,600  
34,600  
34,600  
34,600  
34,600  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
13.00  
12.50  
13.00  
13.00  
13.00  
12.50  
13.00  
12.50  
13.00  
13.00  
13.00  
12.50  
11.15  
11.05  
11.05  
11.15  
11.15  
11.10  
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE  
CC5A/CD5AA042  
CC5A/CD5AW036  
CK5A/CK5BA042  
CK5A/CK5BW036  
34,600  
34,600  
34,600  
34,600  
TDR  
TDR  
TDR  
TDR  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
11.40  
11.35  
11.45  
11.35  
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE  
CC5A/CD5AA042  
CC5A/CD5AW036  
CK5A/CK5BA042  
CK5A/CK5BW036  
34,600  
34,600  
34,600  
34,600  
TDR  
TDR  
TDR  
TDR  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
11.30  
11.25  
11.35  
11.30  
COILS + 355MAV042040 VARIABLE SPEED FURNACE  
CC5A/CD5AA042  
CC5A/CD5AW036  
CK5A/CK5BA042  
CK5A/CK5BW036  
34,600  
34,600  
34,600  
34,600  
TDR  
TDR  
TDR  
TDR  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
11.00  
10.95  
11.05  
11.00  
COILS + 355MAV042060 VARIABLE SPEED FURNACE  
CC5A/CD5AA036  
CK3BA036  
CK5A/CK5BA036  
34,600  
34,600  
34,600  
TDR  
TDR  
TDR  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
10.90  
10.95  
10.95  
036-A  
COILS + 355MAV042080 VARIABLE SPEED FURNACE  
CC5A/CD5AA042  
CC5A/CD5AW036  
CC5A/CD5AW042  
CK5A/CK5BA042  
CK5A/CK5BW036  
34,600  
34,600  
34,600  
34,600  
34,600  
TDR  
TDR  
TDR  
TDR  
TDR  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
11.10  
11.00  
11.00  
11.15  
11.05  
COILS + 355MAV060080 VARIABLE SPEED FURNACE  
CC5A/CD5AW042  
CC5A/CD5AA042  
CC5A/CD5AW036  
CK5A/CK5BA042  
CK5A/CK5BW036  
34,600  
34,600  
34,600  
34,600  
34,600  
TDR  
TDR  
TDR  
TDR  
TDR  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
10.90  
11.00  
10.90  
11.05  
10.95  
COILS + 355MAV060100 VARIABLE SPEED FURNACE  
CC5A/CD5AW042  
CC5A/CD5AA042  
CC5A/CD5AW036  
CK5A/CK5BA042  
CK5A/CK5BW036  
34,600  
34,600  
34,600  
34,600  
34,600  
TDR  
TDR  
TDR  
TDR  
TDR  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
11.15  
11.25  
11.20  
11.30  
11.25  
COILS + 355MAV060120 VARIABLE SPEED FURNACE  
CC5A/CD5AA042  
CC5A/CD5AW036  
CK5A/CK5BA042  
CK5A/CK5BW036  
34,600  
34,600  
34,600  
34,600  
TDR  
TDR  
TDR  
TDR  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
11.20  
11.15  
11.25  
11.20  
CK5A/CK5BA048*  
CC5A/CD5AA042  
CC5A/CD5AC048  
CC5A/CD5AW042  
CC5A/CD5AW048  
CD5AA048  
40,000  
39,500  
39,500  
39,500  
40,000  
40,000  
39,500  
40,000  
39,500  
39,500  
40,000  
39,500  
39,500  
39,500  
40,000  
40,000  
39,500  
40,000  
39,000  
39,500  
40,500  
40,000  
40,500  
38,500  
40,000  
40,500  
38,500  
NONE  
NONE  
12.00  
11.70  
11.70  
11.70  
12.00  
12.00  
12.00  
12.00  
12.00  
11.70  
12.00  
11.70  
12.00  
11.70  
12.00  
12.00  
12.00  
11.70  
11.70  
11.70  
12.00  
12.00  
12.00  
12.00  
12.00  
11.70  
12.00  
11.70  
12.00  
11.70  
12.00  
12.00  
11.70  
12.00  
10.45  
10.40  
10.30  
10.35  
10.40  
10.45  
10.45  
10.50  
10.45  
10.40  
10.45  
10.40  
10.45  
10.40  
10.45  
10.45  
10.25  
10.40  
10.10  
10.25  
10.75  
10.45  
11.80  
11.10  
11.45  
11.80  
11.10  
NONE  
NONE  
NONE  
NONE  
CE3AA042  
NONE  
CE3AA048  
NONE  
CF5AA048  
NONE  
CK3BA042  
NONE  
CK3BA048  
NONE  
CK5A/CK5BA042  
CK5A/CK5BN048  
CK5A/CK5BT042  
CK5A/CK5BT048  
CK5A/CK5BW048  
F(A,B)4AN(F,B,C)042  
F(A,B)4AN(F,B,C)048  
FC4BN(F,B)042  
FC4BN(F,B)048  
FC4BNB054  
NONE  
NONE  
042-A  
NONE  
NONE  
NONE  
TDR  
11.70  
12.00  
11.70  
12.00  
12.20  
TDR  
TDR&TXV  
TDR&TXV  
TDR&TXV  
NONE  
FG3AAA048  
11.70  
11.70  
FK4CNB006  
TDR&TXV  
TDR&TXV  
TDR&TXV  
NONE  
13.50  
12.50  
13.00  
13.70  
12.70  
FK4CNF003  
FK4CNF005  
FV4ANB006  
13.70  
12.70  
FV4ANF003  
NONE  
See notes on page 13.  
—10—  
COMBINATION RATINGS Continued  
SEER  
FACTORY-  
SUPPLIED  
ENHANCE-  
MENT  
Bryant Gas  
Furnace or  
Accessory  
TDR†  
TOT.  
CAP.  
BTUH  
UNIT  
SIZE-SERIES  
INDOOR  
MODEL  
Standard  
Rating  
Accessory  
TXV‡  
EER  
FV4ANF005  
FX4ANF042  
FX4ANF048  
40,500  
38,500  
39,500  
NONE  
NONE  
NONE  
13.20  
11.70  
12.00  
13.20  
11.70  
12.00  
11.45  
10.25  
10.40  
COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE  
CC5A/CD5AA042  
CD5AA048  
39,000  
39,500  
39,000  
39,500  
39,000  
39,500  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
12.20  
12.50  
12.20  
12.50  
12.20  
12.50  
12.20  
12.50  
12.20  
12.50  
12.20  
12.50  
10.95  
11.05  
11.00  
11.10  
11.00  
11.15  
CK3BA042  
CK3BA048  
CK5A/CK5BA042  
CK5A/CK5BA048  
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE  
CC5A/CD5AA042  
CC5A/CD5AW048  
CK5A/CK5BA042  
CK5A/CK5BW048  
39,000  
39,500  
39,000  
39,500  
TDR  
TDR  
TDR  
TDR  
12.50  
13.00  
12.50  
13.00  
12.50  
13.00  
12.50  
13.00  
11.25  
11.30  
11.25  
11.35  
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE  
CC5A/CD5AA042  
CC5A/CD5AW048  
CK5A/CK5BA042  
CK5A/CK5BW048  
39,000  
39,500  
39,000  
39,500  
TDR  
TDR  
TDR  
TDR  
12.50  
13.00  
12.50  
13.00  
12.50  
13.00  
12.50  
13.00  
11.20  
11.30  
11.25  
11.35  
COILS + 355MAV042040 VARIABLE SPEED FURNACE  
CC5A/CD5AA042  
CC5A/CD5AW048  
CK5A/CK5BA042  
CK5A/CK5BW048  
39,000  
39,500  
39,000  
39,500  
TDR  
TDR  
TDR  
TDR  
12.20  
12.50  
12.20  
12.50  
12.20  
12.50  
12.20  
12.50  
10.80  
10.90  
10.80  
10.95  
COILS + 355MAV042060 VARIABLE SPEED FURNACE  
39,000 TDR 12.20  
COILS + 355MAV042080 VARIABLE SPEED FURNACE  
042-A  
CK3BA042  
12.20  
10.80  
CC5A/CD5AA042  
CD5AA048  
39,000  
39,500  
39,000  
39,500  
39,000  
39,500  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
10.90  
11.00  
10.95  
11.10  
10.95  
11.10  
CK3BA042  
CK3BA048  
CK5A/CK5BA042  
CK5A/CK5BA048  
COILS + 355MAV060080 VARIABLE SPEED FURNACE  
CC5A/CD5AA042  
CD5AA048  
39,000  
39,500  
39,000  
39,500  
39,000  
39,500  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
12.20  
12.50  
12.20  
12.50  
12.20  
12.50  
12.20  
12.50  
12.20  
12.50  
12.20  
12.50  
10.80  
10.90  
10.80  
10.95  
10.80  
10.95  
CK3BA042  
CK3BA048  
CK5A/CK5BA042  
CK5A/CK5BA048  
COILS + 355MAV060100 VARIABLE SPEED FURNACE  
CC5A/CD5AA042  
CD5AA048  
39,000  
39,500  
39,000  
39,000  
39,500  
TDR  
TDR  
TDR  
TDR  
TDR  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
11.10  
11.20  
11.15  
11.15  
11.25  
CK3BA042  
CK5A/CK5BA042  
CK5A/CK5BA048  
COILS + 355MAV060120 VARIABLE SPEED FURNACE  
CC5A/CD5AA042  
CC5A/CD5AW048  
CK5A/CK5BA042  
CK5A/CK5BW048  
39,000  
39,500  
39,000  
39,500  
TDR  
TDR  
TDR  
TDR  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
11.10  
11.20  
11.10  
11.25  
CK5A/CK5BA060*  
CC5A/CD5AA060  
CC5A/CD5AC048  
CC5A/CD5AW048  
CC5A/CD5AW060  
CD5AA048  
46,000  
45,000  
44,000  
45,000  
46,500  
45,000  
45,000  
46,000  
44,000  
45,000  
46,000  
45,000  
45,000  
45,000  
46,000  
45,000  
46,000  
45,000  
46,000  
46,500  
44,500  
45,000  
45,000  
46,000  
44,000  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
TDR  
12.00  
11.70  
11.50  
11.70  
12.00  
11.70  
11.70  
12.00  
11.70  
11.70  
12.00  
11.70  
12.00  
11.70  
12.00  
11.70  
12.00  
12.00  
11.70  
11.50  
11.70  
12.00  
11.70  
11.70  
12.00  
11.70  
11.70  
12.00  
11.70  
12.00  
11.70  
12.00  
11.70  
12.00  
11.70  
11.70  
12.00  
10.45  
10.20  
10.10  
10.20  
10.40  
10.20  
10.30  
10.45  
10.25  
10.20  
10.45  
10.20  
10.55  
10.20  
10.45  
10.20  
10.55  
10.15  
10.15  
10.50  
10.05  
10.05  
10.45  
10.40  
10.20  
CE3AA048  
CE3AA060  
CF5AA048  
CK3BA048  
CK3BA060  
CK5A/CK5BA048  
CK5A/CK5BN060  
CK5A/CK5BT048  
CK5A/CK5BT060  
CK5A/CK5BW048  
CK5A/CK5BX060  
F(A,B)4AN(F,B,C)048  
F(A,B)4AN(F,B,C)060  
FB4ANB070  
048-A  
11.70  
11.70  
12.00  
11.50  
11.50  
12.00  
12.00  
TDR  
TDR  
FC4BN(F,B)048  
FC4BN(F,B)060  
FC4BNB054  
FC4BNB070  
FG3AAA048  
TDR&TXV  
TDR&TXV  
TDR&TXV  
TDR&TXV  
NONE  
11.50  
11.50  
See notes on page 13.  
—11—  
COMBINATION RATINGS Continued  
SEER  
FACTORY-  
SUPPLIED  
ENHANCE-  
MENT  
Bryant Gas  
Furnace or  
Accessory  
TDR†  
TOT.  
CAP.  
BTUH  
UNIT  
SIZE-SERIES  
INDOOR  
MODEL  
Standard  
Rating  
Accessory  
TXV‡  
EER  
FG3AAA060  
FK4CNB006  
FK4CNF005  
FV4ANB006  
FV4ANF005  
FX4ANB060  
FX4ANF048  
45,000  
46,000  
45,000  
46,000  
45,000  
45,500  
45,000  
NONE  
TDR&TXV  
TDR&TXV  
NONE  
11.70  
11.70  
10.30  
11.45  
11.15  
11.45  
11.15  
10.40  
10.20  
13.20  
12.50  
13.20  
12.70  
12.00  
11.70  
13.20  
12.70  
12.00  
11.70  
NONE  
NONE  
NONE  
COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE  
CD5AA048  
CK3BA048  
CK5A/CK5BA048  
44,500  
44,500  
44,500  
TDR  
TDR  
TDR  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
10.45  
10.50  
10.50  
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE  
CC5A/CD5AA060  
CC5A/CD5AW048  
CC5A/CD5AW060  
CK3BA060  
CK5A/CK5BA060  
CK5A/CK5BW048  
CK5A/CK5BX060  
45,000  
44,500  
45,500  
45,000  
45,000  
44,500  
46,000  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
12.50  
12.50  
13.00  
12.50  
13.00  
12.50  
13.00  
12.50  
12.50  
13.00  
12.50  
13.00  
12.50  
13.00  
10.95  
10.90  
11.25  
11.25  
11.25  
10.95  
11.40  
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE  
CC5A/CD5AA060  
CC5A/CD5AW048  
CC5A/CD5AW060  
CK3BA060  
CK5A/CK5BA060  
CK5A/CK5BW048  
CK5A/CK5BX060  
45,000  
44,500  
45,500  
45,000  
45,000  
44,500  
46,000  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
13.00  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
13.00  
10.85  
10.80  
11.15  
11.15  
11.15  
10.85  
11.30  
048-A  
COILS + 355MAV042080 VARIABLE SPEED FURNACE  
CD5AA048  
CK5A/CK5BA048  
44,500  
44,500  
TDR  
TDR  
12.00  
12.00  
12.00  
12.00  
10.40  
10.45  
COILS + 355MAV060080 VARIABLE SPEED FURNACE  
CC5A/CD5AW060  
CK3BA048  
CK5A/CK5BA048  
CK5A/CK5BA060  
CK5A/CK5BX060  
46,000  
44,500  
44,500  
45,000  
45,000  
TDR  
TDR  
TDR  
TDR  
TDR  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
10.55  
10.35  
10.35  
10.55  
10.70  
COILS + 355MAV060100 VARIABLE SPEED FURNACE  
CC5A/CD5AA060  
CC5A/CD5AW060  
CD5AA048  
44,500  
45,500  
44,500  
44,500  
44,500  
45,000  
46,000  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
12.00  
12.50  
12.00  
12.00  
12.00  
12.00  
12.50  
12.00  
12.50  
12.00  
12.00  
12.00  
12.00  
12.50  
10.60  
10.85  
10.60  
10.65  
10.65  
10.85  
11.05  
CK3BA048  
CK5A/CK5BA048  
CK5A/CK5BA060  
CK5A/CK5BX060  
COILS + 355MAV060120 VARIABLE SPEED FURNACE  
CC5A/CD5AA060  
CC5A/CD5AW048  
CC5A/CD5AW060  
CK5A/CK5BA060  
CK5A/CK5BW048  
CK5A/CK5BX060  
44,500  
45,000  
45,500  
45,000  
44,500  
46,000  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
12.00  
12.00  
12.50  
12.00  
12.00  
12.50  
12.00  
12.00  
12.50  
12.00  
12.00  
12.50  
10.65  
10.65  
10.90  
10.90  
10.70  
11.05  
CK5A/CK5BA060*  
CC5A/CD5AA060  
CC5A/CD5AW060  
CE3AA060  
58,000  
55,000  
58,000  
57,000  
57,000  
57,000  
58,000  
57,000  
58,000  
57,000  
58,000  
56,000  
58,000  
58,000  
56,000  
NONE  
NONE  
12.00  
11.50  
11.70  
12.00  
12.00  
12.00  
12.00  
12.00  
11.50  
11.70  
12.00  
12.00  
12.00  
12.00  
11.50  
12.00  
10.30  
10.10  
10.30  
10.40  
10.30  
10.30  
10.45  
10.00  
10.40  
9.85  
10.30  
10.20  
10.90  
10.85  
10.25  
NONE  
NONE  
CK3BA060  
NONE  
CK5A/CK5BT060  
CK5A/CK5BX060  
F(A,B)4AN(F,B,C)060  
FB4ANB070  
NONE  
NONE  
TDR  
11.50  
12.00  
11.50  
12.00  
TDR  
FC4BN(F,B)060  
FC4BNB070  
TDR&TXV  
TDR&TXV  
NONE  
FG3AAA060  
11.50  
11.50  
12.50  
12.00  
FK4CNB006  
TDR&TXV  
NONE  
NONE  
12.50  
12.50  
12.00  
FV4ANB006  
060-A  
FX4ANB060  
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE  
CC5A/CD5AA060  
CC5A/CD5AW060  
CK3BA060  
CK5A/CK5BA060  
CK5A/CK5BX060  
56,000  
58,000  
58,000  
58,000  
58,000  
TDR  
TDR  
TDR  
TDR  
TDR  
12.00  
12.00  
12.00  
12.00  
12.50  
12.00  
12.00  
12.00  
12.00  
12.50  
10.30  
10.65  
10.55  
10.55  
10.85  
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE  
CC5A/CD5AA060  
CC5A/CD5AW060  
CK3BA060  
CK5A/CK5BA060  
CK5A/CK5BX060  
56,000  
58,000  
58,000  
58,000  
58,000  
TDR  
TDR  
TDR  
TDR  
TDR  
11.70  
12.00  
12.00  
12.00  
12.50  
11.70  
12.00  
12.00  
12.00  
12.50  
10.20  
10.55  
10.45  
10.45  
10.75  
See notes on page 13.  
—12—  
* Tested combination.  
† In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use  
either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR.  
‡ Based on computer simulation. TXV must be Puron® compatible and hard shutoff type.  
** Ratings shown are with R-22 TXV replaced with Puron® TXV.  
EER — Energy Efficiency Ratio  
SEER — Seasonal Energy Efficiency Ratio  
TDR — Time-Delay Relay  
TXV  
— Thermostatic Expansion Valve  
NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.  
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for electric air conditioners. Ratings for other com-  
binations are determined under DOE computer simulation procedures.  
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.  
4. Do not apply with capillary tube coils as performance and reliability are significantly affected.  
—13—  
DETAILED COOLING CAPACITIES*  
CONDENSER ENTERING AIR TEMPERATURES °F  
EVAP  
AIR  
75  
85  
95  
105  
Capacity  
MBtuh†  
115  
Capacity  
MBtuh†  
125  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
CFM EWB Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw**  
533AN024-A Outdoor Section With CK5AA030 Indoor Section  
72  
67  
26.7  
25.2  
22.4  
21.9  
20.6  
13.0  
16.7  
15.9  
19.5  
20.6  
1.84  
1.83  
1.80  
1.79  
1.77  
25.7  
24.1  
20.9  
20.4  
19.3  
12.6  
16.3  
15.2  
18.8  
19.3  
2.06  
2.04  
1.99  
1.99  
1.97  
24.6  
22.8  
19.3  
18.9  
18.6  
12.2  
15.8  
14.4  
18.1  
18.6  
2.29  
2.27  
2.21  
2.21  
2.20  
23.3  
21.5  
18.3  
18.0  
17.9  
11.8  
15.2  
14.0  
17.7  
17.9  
2.56  
2.53  
2.46  
2.46  
2.45  
22.0  
19.9  
17.3  
17.1  
17.0  
11.3  
14.6  
13.6  
17.1  
17.0  
2.85  
2.80  
2.74  
2.73  
2.73  
20.4  
17.3  
15.3  
15.7  
15.9  
10.8  
13.6  
12.8  
15.7  
15.9  
3.17  
3.08  
3.02  
3.03  
3.04  
700  
800  
900  
63††  
62  
57  
72  
67  
26.9  
25.4  
23.7  
23.2  
22.1  
13.3  
17.4  
17.1  
21.3  
22.1  
1.88  
1.86  
1.85  
1.84  
1.83  
26.0  
24.3  
22.1  
21.7  
20.8  
13.0  
17.1  
16.4  
20.6  
20.8  
2.09  
2.08  
2.05  
2.04  
2.03  
24.9  
23.2  
20.4  
20.2  
20.0  
12.6  
16.7  
15.7  
19.8  
20.0  
2.33  
2.31  
2.27  
2.26  
2.26  
23.8  
21.9  
19.5  
19.3  
19.2  
12.3  
16.2  
15.3  
19.3  
19.2  
2.60  
2.57  
2.52  
2.52  
2.52  
22.3  
20.2  
17.9  
18.5  
18.4  
11.8  
15.6  
14.6  
18.5  
18.4  
2.89  
2.84  
2.79  
2.80  
2.80  
20.7  
17.6  
15.8  
16.6  
16.6  
11.4  
14.6  
13.8  
16.6  
16.6  
3.21  
3.12  
3.07  
3.09  
3.09  
63††  
62  
57  
72  
67  
27.5  
25.6  
24.4  
24.1  
23.4  
13.8  
18.1  
18.1  
22.8  
23.4  
1.92  
1.90  
1.89  
1.89  
1.88  
26.4  
24.4  
23.1  
22.8  
22.0  
13.5  
17.7  
17.6  
22.2  
22.0  
2.14  
2.11  
2.10  
2.10  
2.08  
25.3  
23.4  
21.5  
21.4  
21.3  
13.2  
17.4  
16.9  
21.4  
21.3  
2.38  
2.35  
2.32  
2.32  
2.32  
23.9  
22.1  
20.5  
20.6  
20.4  
12.7  
17.1  
16.5  
20.6  
20.4  
2.64  
2.61  
2.58  
2.58  
2.58  
22.5  
20.5  
18.3  
19.0  
19.0  
12.3  
16.5  
15.6  
19.0  
19.0  
2.93  
2.89  
2.83  
2.85  
2.85  
20.9  
18.0  
16.3  
17.3  
17.1  
11.9  
15.6  
14.8  
17.3  
17.1  
3.26  
3.17  
3.12  
3.15  
3.15  
63††  
62  
57  
Multipliers for Determining the Performance With Other Indoor Sections  
Cooling  
Indoor  
Cooling  
Indoor  
Section  
Size  
Capacity  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.01  
1.03  
1.01  
1.03  
1.00  
1.03  
0.99  
1.02  
1.03  
1.03  
1.03  
1.03  
Power  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
0.99  
0.99  
0.98  
0.98  
1.01  
1.01  
1.00  
0.91  
0.91  
0.90  
0.91  
0.90  
Section  
Size  
Capacity  
Power  
CC5A/CD5AA  
CC5A/CD5AW  
CE3AA  
024  
030  
024  
030  
024  
030  
024  
024  
030  
024  
030  
024  
030  
024  
030  
024  
030  
024  
030  
024  
001  
002  
003  
002  
003  
FX4ANF  
030  
1.03  
0.98  
COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE  
CC5A/CD5AA  
024  
030  
030  
024  
030  
024  
030  
030  
1.00  
1.03  
1.03  
1.00  
1.01  
1.00  
1.03  
1.03  
0.92  
0.92  
0.92  
0.92  
0.92  
0.92  
0.92  
0.92  
CC5A/CD5AW  
CK3BA  
CF5AA  
CK3BA  
CK5A/CK5BA  
CK5A/CK5BW  
CK5A/CK5BA  
CK5A/CK5BW  
F(A,B)4AN(F,C)  
FC4BNF  
COILS + 355MAV042040 VARIABLE SPEED FURNACE  
CC5A/CD5AW  
CK5A/CK5BW  
030  
030  
1.01  
1.01  
0.94  
0.94  
COILS + 355MAV042060 VARIABLE SPEED FURNACE  
CC5A/CD5AW  
024  
030  
024  
030  
024  
030  
1.00  
1.01  
1.00  
1.01  
1.00  
1.01  
0.95  
0.94  
0.95  
0.94  
0.95  
0.94  
CK3BA  
FF1(B,C,D)NA  
CK5A/CK5BW  
FG3AAA  
FK4CNF  
COILS + 355MAV042080 VARIABLE SPEED FURNACE  
CC5A/CD5AW  
024  
030  
024  
030  
1.00  
1.01  
1.00  
1.01  
0.93  
0.93  
0.93  
0.93  
FV4ANF  
CK5A/CK5BW  
See notes on page 19.  
—14—  
DETAILED COOLING CAPACITIES* Continued  
CONDENSER ENTERING AIR TEMPERATURES °F  
EVAP  
AIR  
75  
85  
95  
105  
Capacity  
MBtuh†  
115  
Capacity  
MBtuh†  
125  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
CFM EWB Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw**  
533AN030-A Outdoor Section With CK5AA036 Indoor Section  
72  
67  
33.8  
31.7  
29.1  
28.5  
27.1  
16.9  
22.1  
21.3  
26.6  
27.1  
2.24  
2.22  
2.19  
2.18  
2.17  
32.6  
30.3  
27.1  
26.6  
25.4  
16.5  
21.6  
20.5  
25.6  
25.4  
2.49  
2.46  
2.42  
2.41  
2.39  
31.2  
28.8  
25.0  
24.7  
24.5  
16.0  
21.0  
19.6  
24.6  
24.5  
2.76  
2.73  
2.67  
2.66  
2.66  
29.5  
27.0  
22.8  
22.8  
23.5  
15.5  
20.3  
18.6  
22.8  
23.5  
3.07  
3.03  
2.95  
2.95  
2.96  
27.7  
24.4  
20.4  
21.8  
22.4  
14.9  
19.3  
17.6  
21.8  
22.4  
3.41  
3.34  
3.26  
3.28  
3.30  
25.3  
21.4  
18.9  
20.3  
20.3  
14.1  
18.1  
17.0  
20.3  
20.3  
3.78  
3.68  
3.62  
3.65  
3.65  
1875  
1000  
1125  
63††  
62  
57  
72  
67  
34.1  
32.1  
30.2  
30.0  
29.1  
17.4  
23.2  
23.0  
28.9  
29.1  
2.30  
2.27  
2.25  
2.25  
2.24  
33.0  
30.8  
28.2  
28.1  
27.3  
17.2  
22.9  
22.1  
27.9  
27.3  
2.54  
2.52  
2.48  
2.48  
2.47  
31.6  
29.0  
26.0  
26.3  
26.4  
16.8  
22.2  
21.2  
26.3  
26.4  
2.82  
2.78  
2.74  
2.74  
2.74  
29.9  
27.4  
23.7  
24.6  
25.3  
16.3  
21.7  
20.2  
24.6  
25.3  
3.12  
3.08  
3.02  
3.03  
3.05  
28.0  
24.7  
21.3  
23.4  
23.3  
15.7  
20.7  
19.2  
23.4  
23.3  
3.47  
3.40  
3.32  
3.37  
3.37  
25.5  
21.7  
19.5  
21.0  
21.0  
14.9  
19.5  
18.5  
21.0  
21.0  
3.84  
3.74  
3.68  
3.72  
3.72  
63††  
62  
57  
72  
67  
34.3  
32.4  
30.6  
30.7  
30.7  
18.0  
24.4  
24.3  
30.6  
30.7  
2.35  
2.32  
2.31  
2.31  
2.31  
33.3  
31.0  
29.0  
29.4  
29.0  
17.8  
24.0  
23.6  
29.4  
29.0  
2.60  
2.56  
2.54  
2.55  
2.54  
31.8  
29.3  
26.9  
27.7  
28.0  
17.4  
23.5  
22.7  
27.7  
28.0  
2.87  
2.83  
2.80  
2.81  
2.82  
30.2  
27.7  
24.5  
26.1  
26.5  
17.0  
23.0  
21.7  
26.1  
26.5  
3.18  
3.14  
3.08  
3.11  
3.12  
28.2  
25.2  
22.2  
24.4  
24.1  
16.4  
22.1  
20.7  
24.4  
24.1  
3.52  
3.46  
3.39  
3.44  
3.43  
25.8  
21.9  
19.9  
21.6  
21.7  
15.7  
20.8  
19.6  
21.6  
21.7  
3.90  
3.80  
3.74  
3.79  
3.79  
63††  
62  
57  
Multipliers for Determining the Performance With Other Indoor Sections  
Cooling  
Indoor  
Cooling  
Indoor  
Section  
Size  
Capacity  
0.97  
1.00  
0.97  
1.00  
0.97  
0.97  
0.99  
0.97  
1.00  
0.97  
1.00  
0.97  
1.00  
0.97  
1.00  
0.96  
0.97  
0.96  
0.97  
0.98  
0.98  
0.97  
0.98  
0.98  
1.01  
0.98  
0.99  
1.01  
0.96  
0.97  
Power  
0.99  
1.00  
0.99  
1.00  
1.00  
1.00  
1.00  
0.99  
1.00  
0.99  
1.00  
1.00  
1.00  
0.99  
1.00  
0.99  
1.01  
0.98  
1.00  
1.01  
1.00  
0.92  
0.92  
0.90  
0.90  
0.92  
0.90  
0.90  
0.98  
1.00  
Section  
Size  
036  
030  
Capacity  
1.00  
Power  
0.93  
CC5A/CD5AA  
CC5A/CD5AW  
CE3AA  
030  
036  
030  
036  
030  
036  
036  
030  
036  
030  
036  
036  
036  
030  
036  
030  
036  
030  
036  
030  
036  
001  
002  
003  
005  
002  
003  
005  
030  
036  
CK5A/CK5BA  
CK5A/CK5BW  
0.96  
0.93  
COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE  
CC5A/CD5AW  
030  
036  
030  
036  
0.96  
1.00  
0.96  
1.00  
0.92  
0.91  
0.92  
0.91  
CK5A/CK5BW  
CF5AA  
CK3BA  
COILS + 355MAV042040 VARIABLE SPEED FURNACE  
CC5A/CD5AW  
030  
036  
030  
036  
0.97  
1.00  
0.97  
1.00  
0.96  
0.95  
0.96  
0.95  
CK5A/CK5BA  
CK5A/CK5BW  
CK5A/CK5BN  
CK5A/CK5BT  
CK5A/CK5BW  
COILS + 355MAV042060 VARIABLE SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AW  
CK3BA  
036  
030  
030  
036  
036  
030  
1.00  
0.97  
0.97  
1.00  
1.00  
0.97  
0.96  
0.96  
0.96  
0.96  
0.96  
0.96  
F(A,B)4AN(F,C)  
FC4BNF  
CK5A/CK5BA  
CK5A/CK5BW  
FF1(B,C,D)NA  
FG3AAA  
COILS + 355MAV042080 VARIABLE SPEED FURNACE  
CC5A/CD5AW  
030  
036  
030  
036  
0.97  
1.00  
0.97  
1.00  
0.95  
0.95  
0.95  
0.95  
FK4CNF  
CK5A/CK5BW  
COILS + 355MAV060080 VARIABLE SPEED FURNACE  
FV4ANF  
FX4ANF  
CC5A/CD5AW  
030  
036  
030  
036  
0.97  
1.00  
0.97  
1.00  
0.96  
0.96  
0.96  
0.96  
CK5A/CK5BW  
COILS + 355MAV060100 VARIABLE SPEED FURNACE  
COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE  
CC5A/CD5AW  
030  
036  
030  
036  
0.97  
1.00  
0.97  
1.00  
0.94  
0.93  
0.94  
0.93  
CC5A/CD5AA  
030  
036  
030  
030  
036  
030  
0.96  
1.00  
0.96  
0.96  
1.00  
0.96  
0.93  
0.92  
0.93  
0.93  
0.93  
0.93  
CK5A/CK5BW  
CC5A/CD5AW  
CK3BA  
COILS + 355MAV060120 VARIABLE SPEED FURNACE  
CC5A/CD5AW  
CK5A/CK5BW  
036  
036  
1.00  
1.00  
0.94  
0.94  
CK5A/CK5BA  
See notes on page 19.  
—15—  
DETAILED COOLING CAPACITIES* Continued  
CONDENSER ENTERING AIR TEMPERATURES °F  
EVAP  
AIR  
75  
85  
95  
105  
Capacity  
MBtuh†  
115  
Capacity  
MBtuh†  
125  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
CFM EWB Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw**  
533AN036-A Outdoor Section With CK5AA042 Indoor Section  
72  
67  
40.6  
38.2  
35.9  
35.4  
33.6  
20.1  
26.3  
25.8  
32.2  
33.6  
2.70  
2.68  
2.67  
2.67  
2.64  
39.1  
36.3  
34.1  
32.6  
31.7  
19.6  
25.5  
25.1  
30.8  
31.7  
3.00  
2.98  
2.96  
2.94  
2.92  
37.3  
34.5  
32.0  
29.7  
29.6  
19.0  
24.8  
24.1  
29.4  
29.6  
3.33  
3.30  
3.27  
3.24  
3.23  
35.3  
32.4  
29.6  
28.2  
28.3  
18.3  
24.0  
23.1  
28.2  
28.3  
3.70  
3.66  
3.62  
3.59  
3.59  
33.0  
30.2  
26.8  
26.8  
26.9  
17.6  
23.2  
21.9  
26.8  
26.9  
4.08  
4.04  
3.97  
3.98  
3.98  
30.5  
26.5  
23.4  
24.9  
24.6  
16.8  
21.9  
20.5  
24.9  
24.6  
4.52  
4.43  
4.35  
4.39  
4.38  
1050  
1200  
1350  
63††  
62  
57  
72  
67  
41.1  
38.9  
36.6  
36.2  
35.0  
20.8  
27.8  
27.4  
34.5  
35.0  
2.76  
2.75  
2.73  
2.73  
2.71  
39.6  
36.9  
34.7  
33.4  
33.9  
20.3  
27.0  
26.6  
33.0  
33.9  
3.06  
3.04  
3.02  
3.00  
3.01  
37.8  
35.0  
32.5  
31.7  
31.8  
19.8  
26.4  
25.7  
31.7  
31.8  
3.40  
3.37  
3.34  
3.32  
3.32  
35.7  
32.9  
30.1  
30.2  
30.5  
19.2  
25.6  
24.7  
30.2  
30.5  
3.76  
3.72  
3.68  
3.68  
3.69  
33.4  
30.6  
27.2  
28.7  
29.0  
18.4  
24.9  
23.5  
28.7  
29.0  
4.15  
4.11  
4.04  
4.07  
4.08  
30.8  
26.9  
23.7  
25.9  
25.9  
17.7  
23.5  
22.0  
25.9  
25.9  
4.59  
4.50  
4.42  
4.47  
4.47  
63††  
62  
57  
72  
67  
41.4  
39.1  
37.0  
37.0  
36.9  
21.4  
29.0  
28.8  
36.5  
36.9  
2.82  
2.80  
2.79  
2.79  
2.79  
39.9  
37.4  
35.2  
35.4  
35.4  
21.0  
28.5  
28.1  
35.4  
35.4  
3.13  
3.10  
3.08  
3.09  
3.09  
38.1  
35.4  
32.9  
33.6  
33.7  
20.5  
27.8  
27.1  
33.6  
33.7  
3.46  
3.43  
3.40  
3.41  
3.41  
36.0  
33.3  
30.4  
31.8  
31.8  
19.9  
27.1  
26.1  
31.8  
31.8  
3.82  
3.78  
3.74  
3.76  
3.76  
33.7  
31.0  
27.5  
29.8  
29.8  
19.2  
26.5  
24.9  
29.8  
29.8  
4.22  
4.18  
4.11  
4.16  
4.16  
31.0  
27.5  
24.1  
26.7  
27.0  
18.6  
25.1  
23.4  
26.7  
27.0  
4.65  
4.58  
4.49  
4.56  
4.56  
63††  
62  
57  
Multipliers for Determining the Performance With Other Indoor Sections  
Cooling  
Cooling  
Indoor  
Section  
Indoor  
Section  
Size  
Capacity  
1.00  
1.00  
1.00  
0.99  
0.99  
1.00  
0.99  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
0.97  
1.00  
0.97  
0.97  
1.01  
0.97  
0.97  
0.98  
1.00  
1.02  
0.97  
0.98  
1.00  
0.97  
Power  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.01  
1.02  
1.00  
1.01  
1.00  
0.90  
0.94  
0.94  
0.91  
0.91  
0.90  
0.94  
0.91  
0.91  
1.00  
Size  
Capacity  
Power  
CC5A/CD5AA  
CC5A/CD5AW  
CE3AA  
036  
042  
036  
042  
036  
042  
036  
036  
042  
036  
042  
036  
042  
036  
042  
036  
042  
036  
036  
006  
001  
002  
003  
005  
006  
002  
003  
005  
042  
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AW  
CK5A/CK5BA  
CK5A/CK5BW  
042  
036  
042  
036  
0.99  
0.99  
0.99  
0.99  
0.92  
0.92  
0.92  
0.92  
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE  
CF5AA  
CK3BA  
CC5A/CD5AA  
CC5A/CD5AW  
CK5A/CK5BA  
CK5A/CK5BW  
042  
036  
042  
036  
0.99  
0.99  
0.99  
0.99  
0.92  
0.92  
0.92  
0.92  
CK5A/CK5BA  
CK5A/CK5BN  
CK5A/CK5BT  
COILS + 355MAV042040 VARIABLE SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AW  
CK5A/CK5BA  
CK5A/CK5BW  
042  
036  
042  
036  
0.99  
0.99  
0.99  
0.99  
0.93  
0.94  
0.93  
0.94  
CK5A/CK5BW  
F(A,B)4AN(F,B,C)  
F(A,B)4AN(F,C)  
FC4BN(F,B)  
FCBNF  
COILS + 355MAV042060 VARIABLE SPEED FURNACE  
CC5A/CD5AA  
CK3BA  
036  
036  
036  
0.99  
0.99  
0.99  
0.94  
0.94  
0.94  
FG3AAA  
CK5A/CK5BA  
FK4CNB  
COILS + 355MAV042080 VARIABLE SPEED FURNACE  
FK4CNF  
CC5A/CD5AA  
CC5A/CD5AW  
042  
036  
042  
042  
036  
0.99  
0.99  
0.99  
0.99  
0.99  
0.93  
0.93  
0.93  
0.93  
0.93  
CK5A/CK5BA  
CK5A/CK5BW  
FV4ANB  
FV4ANF  
COILS + 355MAV060080 VARIABLE SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AW  
042  
036  
042  
042  
036  
0.99  
0.99  
0.99  
0.99  
0.99  
0.93  
0.94  
0.93  
0.94  
0.94  
FX4ANF  
COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE  
CK5A/CK5BA  
CK5A/CK5BW  
CC5A/CD5AA  
CK3BA  
036  
036  
036  
0.99  
0.99  
0.99  
0.95  
0.95  
0.95  
COILS + 355MAV060100 VARIABLE SPEED FURNACE  
CK5A/CK5BA  
CC5A/CD5AA  
CC5A/CD5AW  
042  
036  
042  
042  
036  
0.99  
0.99  
0.99  
0.99  
0.99  
0.92  
0.92  
0.92  
0.92  
0.92  
COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AW  
042  
036  
042  
042  
042  
036  
0.99  
0.99  
0.99  
0.99  
0.99  
0.99  
0.93  
0.94  
0.93  
0.93  
0.93  
0.94  
CK5A/CK5BA  
CK5A/CK5BW  
CK3BA  
COILS + 355MAV060120 VARIABLE SPEED FURNACE  
CK5A/CK5BA  
CK5A/CK5BW  
CC5A/CD5AA  
CC5A/CD5AW  
CK5A/CK5BA  
CK5A/CK5BW  
042  
036  
042  
036  
0.99  
0.99  
0.99  
0.99  
0.92  
0.92  
0.92  
0.92  
See notes on page 19.  
—16—  
DETAILED COOLING CAPACITIES* Continued  
CONDENSER ENTERING AIR TEMPERATURES °F  
EVAP  
AIR  
75  
85  
95  
105  
Capacity  
MBtuh†  
115  
Capacity  
MBtuh†  
125  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
CFM EWB Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw**  
533AN042-A Outdoor Section With CK5AA048 Indoor Section  
72  
67  
46.5  
44.0  
38.6  
38.1  
37.3  
23.0  
30.4  
28.5  
35.8  
37.3  
3.09  
3.06  
2.98  
2.97  
2.96  
45.1  
41.9  
35.8  
35.4  
35.1  
22.7  
29.6  
27.3  
34.4  
35.1  
3.44  
3.39  
3.29  
3.29  
3.28  
43.0  
39.6  
33.1  
33.1  
33.8  
21.9  
28.6  
26.2  
33.1  
33.8  
3.81  
3.77  
3.64  
3.64  
3.65  
40.7  
37.3  
31.8  
32.0  
32.4  
21.2  
27.7  
25.6  
32.0  
32.4  
4.23  
4.17  
4.06  
4.07  
4.08  
38.1  
34.4  
30.2  
30.7  
30.8  
20.3  
26.6  
25.0  
30.7  
30.8  
4.69  
4.61  
4.53  
4.54  
4.54  
35.2  
30.2  
26.6  
28.1  
28.1  
19.4  
25.0  
23.5  
28.1  
28.1  
5.20  
5.09  
4.99  
5.03  
5.03  
1225  
1400  
1575  
63††  
62  
57  
72  
67  
47.1  
44.5  
39.7  
39.2  
38.9  
23.9  
32.0  
30.5  
38.4  
38.9  
3.16  
3.13  
3.07  
3.06  
3.05  
45.3  
42.2  
36.8  
37.7  
37.6  
23.3  
31.0  
29.3  
37.5  
37.6  
3.50  
3.46  
3.38  
3.39  
3.39  
43.2  
40.0  
34.4  
35.5  
36.2  
22.7  
30.2  
28.3  
35.5  
36.2  
3.88  
3.83  
3.74  
3.76  
3.77  
41.0  
37.8  
33.1  
34.4  
34.8  
22.0  
29.5  
27.7  
34.4  
34.8  
4.30  
4.24  
4.16  
4.19  
4.20  
38.4  
35.2  
31.2  
32.8  
32.4  
21.2  
28.6  
26.9  
32.8  
32.4  
4.75  
4.70  
4.61  
4.64  
4.64  
35.6  
30.9  
27.6  
29.8  
29.6  
20.4  
27.0  
25.4  
29.8  
29.6  
5.29  
5.18  
5.08  
5.14  
5.14  
63††  
62  
57  
72  
67  
47.6  
44.9  
41.0  
41.5  
41.3  
24.7  
33.4  
32.5  
41.3  
41.3  
3.24  
3.20  
3.15  
3.16  
3.16  
45.9  
42.5  
39.1  
39.9  
39.8  
24.3  
32.5  
31.7  
39.9  
39.8  
3.59  
3.53  
3.48  
3.50  
3.49  
43.7  
40.4  
35.9  
37.6  
38.4  
23.7  
31.9  
30.4  
37.6  
38.4  
3.96  
3.90  
3.83  
3.87  
3.88  
41.4  
38.1  
34.2  
36.5  
36.5  
23.0  
31.1  
29.7  
36.5  
36.5  
4.38  
4.31  
4.25  
4.29  
4.29  
38.7  
35.6  
32.0  
34.0  
33.8  
22.2  
30.4  
28.7  
34.0  
33.8  
4.84  
4.78  
4.70  
4.74  
4.74  
35.8  
31.6  
28.0  
31.0  
30.9  
21.4  
28.8  
27.0  
31.0  
30.9  
5.38  
5.26  
5.17  
5.24  
5.24  
63††  
62  
57  
Multipliers for Determining the Performance With Other Indoor Sections  
Cooling  
Cooling  
Indoor  
Indoor  
Section  
Size  
Capacity  
0.99  
0.99  
0.99  
1.00  
1.00  
0.99  
1.00  
0.99  
0.99  
1.00  
0.99  
1.00  
0.99  
0.99  
1.00  
1.00  
0.99  
1.00  
0.98  
0.99  
1.01  
1.00  
1.01  
0.96  
1.00  
1.01  
0.96  
1.01  
0.96  
0.99  
Power  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.01  
1.02  
1.00  
1.00  
0.99  
1.00  
0.90  
0.91  
0.92  
0.90  
0.91  
0.92  
1.00  
1.00  
Section  
Size  
042  
048  
Capacity  
0.98  
Power  
0.92  
CC5A/CD5AA  
CC5A/CD5AC  
CC5A/CD5AW  
042  
048  
042  
048  
048  
042  
048  
048  
042  
048  
042  
048  
048  
042  
048  
048  
042  
048  
042  
048  
054  
048  
006  
003  
005  
006  
003  
005  
042  
048  
CK5A/CK5BA  
CK5A/CK5BW  
0.99  
0.92  
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AW  
CK5A/CK5BA  
CK5A/CK5BW  
042  
048  
042  
048  
0.98  
0.99  
0.98  
0.99  
0.93  
0.92  
0.93  
0.92  
CD5AA  
CE3AA  
CF5AA  
CK3BA  
COILS + 355MAV042040 VARIABLE SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AW  
CK5A/CK5BA  
CK5A/CK5BW  
042  
048  
042  
048  
0.98  
0.99  
0.98  
0.99  
0.95  
0.95  
0.95  
0.95  
CK5A/CK5BA  
CK5A/CK5BN  
CK5A/CK5BT  
COILS + 355MAV042060 VARIABLE SPEED FURNACE  
CK3BA 042 0.98 0.95  
COILS + 355MAV042080 VARIABLE SPEED FURNACE  
CK5A/CK5BW  
CC5A/CD5AA  
CD5AA  
042  
048  
042  
048  
042  
048  
0.98  
0.99  
0.98  
0.99  
0.98  
0.99  
0.94  
0.94  
0.94  
0.94  
0.94  
0.94  
F(A,B)4AN(F,B,C)  
CK3BA  
FC4BN(F,B)  
CK5A/CK5BA  
FC4BNB  
FG3AAA  
FK4CNB  
FK4CNF  
COILS + 355MAV060080 VARIABLE SPEED FURNACE  
CC5A/CD5AA  
CD5AA  
042  
048  
042  
048  
042  
048  
0.98  
0.99  
0.98  
0.99  
0.98  
0.99  
0.95  
0.95  
0.95  
0.95  
0.95  
0.95  
CK3BA  
FV4ANB  
FV4ANF  
CK5A/CK5BA  
FX4ANF  
COILS + 355MAV060100 VARIABLE SPEED FURNACE  
CC5A/CD5AA  
CD5AA  
042  
048  
042  
042  
048  
0.98  
0.99  
0.98  
0.98  
0.99  
0.93  
0.93  
0.93  
0.93  
0.93  
COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE  
CC5A/CD5AA  
CD5AA  
042  
048  
042  
048  
042  
048  
0.98  
0.99  
0.98  
0.99  
0.98  
0.99  
0.94  
0.94  
0.94  
0.94  
0.94  
0.94  
CK3BA  
CK5A/CK5BA  
CK3BA  
COILS + 355MAV060120 VARIABLE SPEED FURNACE  
CK5A/CK5BA  
CC5A/CD5AA  
CC5A/CD5AW  
CK5A/CK5BA  
CK5A/CK5BW  
042  
048  
042  
048  
0.98  
0.99  
0.98  
0.99  
0.93  
0.93  
0.93  
0.93  
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AW  
042  
048  
0.98  
0.99  
0.92  
0.92  
See notes on page 19.  
—17—  
DETAILED COOLING CAPACITIES* Continued  
CONDENSER ENTERING AIR TEMPERATURES °F  
EVAP  
AIR  
75  
85  
95  
105  
Capacity  
MBtuh†  
115  
Capacity  
MBtuh†  
125  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
CFM EWB Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw**  
533AN048-A Outdoor Section With CK5AA060 Indoor Section  
72  
67  
53.1  
49.9  
46.8  
46.2  
44.7  
26.3  
34.4  
33.8  
42.1  
44.7  
3.58  
3.53  
3.49  
3.48  
3.46  
51.2  
47.7  
44.6  
42.7  
42.3  
25.7  
33.5  
32.9  
40.5  
42.3  
3.96  
3.90  
3.85  
3.83  
3.82  
49.3  
45.3  
40.8  
39.1  
39.7  
25.2  
32.6  
31.2  
38.7  
39.7  
4.40  
4.31  
4.24  
4.22  
4.23  
47.0  
42.9  
36.7  
37.0  
37.0  
24.4  
31.8  
29.5  
37.0  
37.0  
4.88  
4.79  
4.68  
4.68  
4.68  
44.1  
39.8  
34.0  
34.9  
35.3  
23.5  
30.6  
28.3  
34.9  
35.3  
5.41  
5.31  
5.18  
5.21  
5.21  
41.0  
35.3  
31.0  
32.4  
32.2  
22.4  
28.9  
27.1  
32.4  
32.2  
6.03  
5.87  
5.76  
5.80  
5.80  
1400  
1600  
1800  
63††  
62  
57  
72  
67  
53.7  
50.5  
47.7  
47.2  
46.7  
27.3  
36.2  
35.9  
45.2  
46.7  
3.67  
3.61  
3.58  
3.57  
3.57  
51.8  
48.3  
45.4  
44.1  
44.1  
26.7  
35.4  
34.9  
43.6  
44.1  
4.05  
3.98  
3.95  
3.93  
3.93  
50.0  
46.0  
41.4  
42.0  
41.7  
26.3  
34.8  
33.3  
42.0  
41.7  
4.49  
4.41  
4.34  
4.35  
4.34  
47.4  
43.5  
37.6  
40.0  
40.1  
25.5  
34.0  
31.7  
40.0  
40.1  
4.96  
4.88  
4.77  
4.82  
4.82  
44.4  
40.3  
34.8  
37.8  
37.4  
24.6  
32.8  
30.5  
37.8  
37.4  
5.49  
5.41  
5.28  
5.34  
5.34  
41.4  
35.8  
31.7  
33.8  
34.2  
23.7  
31.1  
29.2  
33.8  
34.2  
6.13  
5.97  
5.86  
5.92  
5.93  
63††  
62  
57  
72  
67  
54.0  
50.8  
48.2  
48.1  
47.9  
28.1  
37.7  
37.6  
47.7  
47.9  
3.75  
3.69  
3.66  
3.66  
3.65  
52.2  
48.9  
46.0  
46.2  
46.2  
27.6  
37.4  
36.9  
46.2  
46.2  
4.13  
4.07  
4.04  
4.04  
4.04  
50.0  
46.5  
43.5  
44.2  
44.2  
27.1  
36.8  
35.9  
44.2  
44.2  
4.56  
4.50  
4.45  
4.46  
4.46  
47.5  
44.0  
40.0  
42.0  
42.0  
26.4  
36.0  
34.4  
42.0  
42.0  
5.03  
4.98  
4.89  
4.94  
4.94  
44.8  
40.8  
35.9  
39.3  
39.2  
25.7  
34.9  
32.7  
39.3  
39.2  
5.58  
5.50  
5.39  
5.46  
5.46  
41.7  
36.0  
32.4  
35.0  
35.5  
24.8  
33.1  
31.2  
35.0  
35.5  
6.23  
6.07  
5.96  
6.04  
6.04  
63††  
62  
57  
Multipliers for Determining the Performance With Other Indoor Sections  
Cooling  
Indoor  
Cooling  
Indoor  
Section  
Size  
Capacity  
0.98  
0.96  
0.98  
1.01  
0.98  
0.98  
1.00  
0.96  
0.98  
1.00  
0.98  
1.00  
0.98  
0.98  
1.00  
0.98  
1.00  
0.98  
1.00  
1.01  
0.97  
0.98  
0.98  
1.00  
0.96  
0.98  
1.00  
0.98  
1.00  
0.98  
0.99  
0.98  
Power  
0.99  
0.98  
0.99  
1.00  
0.99  
1.00  
1.00  
0.98  
0.99  
1.00  
0.99  
1.00  
1.00  
0.99  
1.00  
0.99  
1.00  
1.02  
1.03  
1.02  
0.99  
1.00  
0.99  
0.99  
0.99  
1.00  
0.90  
0.91  
0.90  
0.91  
0.99  
0.99  
Section  
Size  
048  
060  
060  
060  
048  
060  
Capacity  
0.97  
Power  
0.93  
0.92  
0.93  
0.93  
0.93  
0.93  
CC5A/CD5AA  
CC5A/CD5AC  
CC5A/CD5AW  
060  
048  
048  
060  
048  
048  
060  
048  
048  
060  
048  
060  
060  
048  
060  
048  
060  
048  
060  
070  
048  
060  
054  
070  
048  
060  
006  
005  
006  
005  
060  
048  
CC5A/CD5AW  
0.99  
CK3BA  
0.98  
CK5A/CK5BA  
CK5A/CK5BW  
CK5A/CK5BX  
0.98  
CD5AA  
CE3AA  
0.97  
1.00  
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE  
CF5AA  
CK3BA  
CC5A/CD5AA  
CC5A/CD5AW  
060  
048  
060  
060  
060  
048  
060  
0.98  
0.97  
0.99  
0.98  
0.98  
0.97  
1.00  
0.93  
0.93  
0.93  
0.94  
0.94  
0.93  
0.94  
CK5A/CK5BA  
CK3BA  
CK5A/CK5BA  
CK5A/CK5BW  
CK5A/CK5BX  
CK5A/CK5BN  
CK5A/CK5BT  
COILS + 355MAV042080 VARIABLE SPEED FURNACE  
CK5A/CK5BW  
CK5A/CK5BX  
CD5AA  
048  
048  
0.97  
0.97  
0.96  
0.96  
CK5A/CK5BA  
F(A,B)4AN(F,B,C)  
COILS + 355MAV060080 VARIABLE SPEED FURNACE  
CC5A/CD5AW  
CK3BA  
060  
048  
048  
060  
060  
1.00  
0.97  
0.97  
0.98  
0.98  
0.97  
0.97  
0.97  
0.98  
0.97  
FB4ANB  
FC4BN(F,B)  
CK5A/CK5BA  
FC4BNB  
FG3AAA  
CK5A/CK5BX  
COILS + 355MAV060100 VARIABLE SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AW  
CD5AA  
060  
060  
048  
048  
048  
060  
060  
0.97  
0.99  
0.97  
0.97  
0.97  
0.98  
1.00  
0.95  
0.95  
0.95  
0.95  
0.95  
0.95  
0.95  
FK4CNB  
FK4CNF  
FV4ANB  
FV4ANF  
FX4ANB  
FX4ANF  
CK3BA  
CK5A/CK5BA  
CK5A/CK5BX  
COILS + 355MAV060120 VARIABLE SPEED FURNACE  
COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AW  
060  
048  
060  
060  
048  
060  
0.97  
0.98  
0.99  
0.98  
0.97  
1.00  
0.94  
0.94  
0.95  
0.95  
0.95  
0.95  
CD5AA  
CK3BA  
048  
048  
048  
0.97  
0.97  
0.97  
0.96  
0.96  
0.96  
CK5A/CK5BA  
CK5A/CK5BA  
CK5A/CK5BW  
CK5A/CK5BX  
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE  
CC5A/CD5AA  
060  
0.98  
0.92  
See notes on page 19.  
—18—  
DETAILED COOLING CAPACITIES* Continued  
CONDENSER ENTERING AIR TEMPERATURES °F  
EVAP  
AIR  
75  
85  
95  
105  
Capacity  
MBtuh†  
115  
Capacity  
MBtuh†  
125  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
CFM EWB Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw**  
533AN060-A Outdoor Section With CK5AA060 Indoor Section  
72  
67.5  
62.8  
55.5  
54.2  
50.9  
32.8  
41.9  
39.5  
48.8  
50.9  
4.50  
4.44  
4.32  
4.30  
4.25  
64.6  
59.7  
51.6  
50.5  
47.8  
31.8  
40.6  
37.8  
47.1  
47.8  
4.99  
4.91  
4.77  
4.75  
4.70  
61.6  
56.7  
47.6  
46.7  
46.1  
30.7  
39.4  
36.0  
45.2  
46.1  
5.54  
5.45  
5.27  
5.26  
5.25  
58.3  
53.3  
45.3  
44.5  
44.2  
29.5  
38.0  
35.1  
44.1  
44.2  
6.14  
6.06  
5.88  
5.86  
5.85  
54.8  
49.9  
42.7  
42.7  
42.4  
28.3  
36.7  
33.9  
42.7  
42.4  
6.81  
6.71  
6.55  
6.55  
6.54  
50.8  
44.2  
39.1  
40.2  
40.4  
26.9  
34.5  
32.5  
40.2  
40.4  
7.57  
7.42  
7.28  
7.30  
7.30  
67  
1600 63††  
62  
57  
72  
68.2  
63.8  
56.6  
55.5  
52.9  
33.7  
43.9  
41.6  
51.9  
52.9  
4.58  
4.52  
4.41  
4.40  
4.36  
65.4  
60.8  
52.6  
51.8  
51.2  
32.8  
42.8  
39.9  
50.1  
51.2  
5.08  
5.01  
4.87  
4.85  
4.84  
62.4  
57.4  
50.4  
49.7  
49.4  
31.7  
41.4  
39.0  
49.1  
49.4  
5.63  
5.54  
5.41  
5.39  
5.38  
59.0  
54.1  
48.0  
47.7  
47.4  
30.6  
40.1  
38.0  
47.7  
47.4  
6.24  
6.15  
6.01  
6.01  
6.00  
55.4  
50.5  
45.4  
45.8  
45.6  
29.4  
38.8  
36.8  
45.8  
45.6  
6.91  
6.82  
6.69  
6.70  
6.70  
51.3  
44.8  
39.9  
41.7  
41.9  
28.1  
36.6  
34.6  
41.7  
41.9  
7.66  
7.52  
7.38  
7.43  
7.43  
67  
1800 63††  
62  
57  
72  
68.8  
64.4  
57.6  
56.8  
56.1  
34.6  
45.6  
43.6  
54.9  
56.1  
4.67  
4.60  
4.51  
4.49  
4.48  
66.0  
61.5  
53.9  
54.7  
54.1  
33.7  
44.6  
42.1  
53.9  
54.1  
5.16  
5.09  
4.96  
4.97  
4.97  
62.9  
58.0  
52.9  
52.5  
52.3  
32.7  
43.2  
41.7  
52.5  
52.3  
5.72  
5.62  
5.53  
5.52  
5.52  
59.5  
54.7  
50.5  
50.5  
50.3  
31.7  
42.1  
40.7  
50.5  
50.3  
6.33  
6.23  
6.14  
6.15  
6.14  
55.8  
51.1  
45.6  
47.8  
47.8  
30.5  
40.9  
38.7  
47.8  
47.8  
7.00  
6.91  
6.78  
6.82  
6.82  
51.7  
45.8  
40.5  
43.0  
43.1  
29.2  
38.9  
36.6  
43.0  
43.1  
7.75  
7.62  
7.47  
7.55  
7.55  
67  
2000 63††  
62  
57  
Multipliers for Determining the Performance With Other Indoor Sections  
Cooling  
Indoor  
Cooling  
Indoor  
Section  
Size  
Capacity  
0.95  
1.00  
0.98  
0.98  
1.00  
0.98  
1.00  
0.98  
1.00  
0.98  
1.00  
0.97  
1.00  
1.00  
Power  
0.98  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.04  
1.02  
1.03  
1.01  
1.00  
0.95  
0.95  
Section  
Size  
Capacity  
Power  
CC5A/CD5AA  
CC5A/CD5AW  
CE3AA  
060  
060  
060  
060  
060  
060  
060  
060  
070  
060  
070  
060  
006  
006  
FX4ANB  
060  
0.97  
1.01  
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AW  
CK3BA  
060  
060  
060  
060  
060  
0.97  
1.00  
1.00  
1.00  
1.00  
0.96  
0.96  
0.96  
0.96  
0.96  
CK3BA  
CK5A/CK5BA  
CK5A/CK5BT  
CK5A/CK5BX  
F(A,B)4AN(F,B,C)  
FB4ANB  
CK5A/CK5BA  
CK5A/CK5BX  
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AW  
CK3BA  
060  
060  
060  
060  
060  
0.97  
1.00  
1.00  
1.00  
1.00  
0.97  
0.96  
0.97  
0.97  
0.97  
FC4BN(F,B)  
FC4BNB  
FG3AAA  
CK5A/CK5BA  
CK5A/CK5BX  
FK4CNB  
FV4ANB  
* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length and/or  
indoor unit is located above outdoor unit, a slight variation in capacity may occur.  
Total and sensible capacities are net capacities. Blower motor heat has been subtracted.  
‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh  
(245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air  
per degree above 80°F (27°C). When the required data falls between the published data, interpolation may be performed.  
** Unit kw is outdoor unit kilowatts only.  
†† At TVA rating indoor condition (75°F edb/63°F ewb). All other indoor air temperatures are at 80°F edb.  
‡‡ Data are with FC4 and FK4 R-22 TXV replaced with Puron® TXV.  
—19—  
CONDENSER ONLY RATINGS*  
CONDENSER ENTERING AIR TEMPERATURES °F  
SST  
°F  
55  
65  
75  
85  
95  
105  
115  
125  
533AN024-A  
TCG  
SDT  
KW  
23.3  
76.9  
1.20  
22.1  
86.8  
1.37  
20.8  
96.6  
1.55  
19.6  
107.  
1.76  
18.3  
117.  
1.98  
17.0  
127.  
2.22  
15.7  
136.  
2.48  
14.4  
146.  
2.74  
30  
35  
40  
45  
50  
55  
TCG  
SDT  
KW  
25.6  
78.1  
1.20  
24.3  
87.9  
1.37  
22.9  
97.7  
1.56  
21.5  
108.  
1.76  
20.2  
117.  
1.99  
18.7  
127.  
2.24  
17.3  
137.  
2.50  
15.9  
147.  
2.76  
TCG  
SDT  
KW  
28.1  
79.5  
1.20  
26.6  
89.2  
1.37  
25.1  
98.9  
1.57  
23.6  
109.  
1.78  
22.1  
119.  
2.00  
20.6  
128.  
2.25  
19.0  
138.  
2.52  
17.4  
148.  
2.79  
TCG  
SDT  
KW  
30.6  
81.1  
1.20  
29.0  
90.7  
1.38  
27.4  
100.  
1.58  
25.8  
110.  
1.79  
24.2  
120.  
2.02  
22.5  
130.  
2.27  
20.8  
140.  
2.55  
19.1  
149.  
2.82  
TCG  
SDT  
KW  
33.4  
82.8  
1.21  
31.6  
92.4  
1.39  
29.9  
102.  
1.59  
28.2  
112.  
1.80  
26.4  
121.  
2.04  
24.6  
131.  
2.30  
22.7  
141.  
2.57  
20.8  
151.  
2.85  
TCG  
SDT  
KW  
36.2  
84.7  
1.22  
34.4  
94.2  
1.40  
32.5  
104.  
1.60  
30.6  
113.  
1.82  
28.7  
123.  
2.06  
26.7  
133.  
2.32  
24.7  
142.  
2.60  
22.6  
152.  
2.88  
533AN030-A  
TCG  
SDT  
KW  
26.7  
76.8  
1.44  
25.2  
86.6  
1.63  
23.8  
96.5  
1.84  
22.4  
106.  
2.09  
20.9  
116.  
2.36  
19.5  
126.  
2.67  
18.0  
136.  
3.01  
16.4  
146.  
3.39  
30  
35  
40  
45  
50  
55  
TCG  
SDT  
KW  
29.3  
77.9  
1.44  
27.7  
87.6  
1.63  
26.2  
97.4  
1.85  
24.6  
107.  
2.09  
23.1  
117.  
2.37  
21.5  
127.  
2.68  
19.8  
137.  
3.02  
18.1  
147.  
3.39  
TCG  
SDT  
KW  
32.1  
79.2  
1.46  
30.4  
88.9  
1.65  
28.7  
98.6  
1.86  
27.0  
108.  
2.10  
25.3  
118.  
2.38  
23.6  
128.  
2.68  
21.8  
138.  
3.02  
19.9  
148.  
3.40  
TCG  
SDT  
KW  
35.0  
80.7  
1.47  
33.2  
90.3  
1.66  
31.4  
100.  
1.88  
29.6  
110.  
2.12  
27.7  
119.  
2.39  
25.8  
129.  
2.70  
23.8  
139.  
3.04  
21.8  
149.  
3.42  
TCG  
SDT  
KW  
38.2  
82.4  
1.49  
36.2  
91.9  
1.68  
34.2  
101.  
1.90  
32.2  
111.  
2.14  
30.2  
121.  
2.41  
28.2  
131.  
2.72  
26.0  
140.  
3.06  
23.7  
150.  
3.44  
TCG  
SDT  
KW  
41.4  
84.2  
1.51  
39.3  
93.7  
1.71  
37.2  
103.  
1.92  
35.1  
113.  
2.16  
32.9  
122.  
2.44  
30.7  
132.  
2.74  
28.3  
142.  
3.08  
25.8  
151.  
3.46  
533AN036-A  
TCG  
SDT  
KW  
32.3  
77.0  
1.76  
30.5  
86.7  
2.00  
28.7  
96.6  
2.27  
26.8  
106.  
2.55  
24.9  
116.  
2.86  
22.8  
126.  
3.19  
20.7  
136.  
3.53  
18.3  
146.  
3.87  
30  
35  
40  
45  
50  
TCG  
SDT  
KW  
35.4  
78.2  
1.76  
33.6  
87.9  
2.00  
31.7  
97.6  
2.27  
29.7  
107.  
2.56  
27.6  
117.  
2.88  
25.4  
127.  
3.21  
23.1  
137.  
3.56  
20.7  
146.  
3.93  
TCG  
SDT  
KW  
38.8  
79.6  
1.76  
36.8  
89.2  
2.00  
34.7  
98.9  
2.27  
32.6  
109.  
2.57  
30.4  
118.  
2.89  
28.1  
128.  
3.24  
25.7  
138.  
3.60  
23.1  
147.  
3.98  
TCG  
SDT  
KW  
42.3  
81.2  
1.77  
40.2  
90.7  
2.01  
38.0  
100.  
2.28  
35.7  
110.  
2.58  
33.4  
120.  
2.91  
30.9  
129.  
3.26  
28.3  
139.  
3.63  
25.5  
148.  
4.03  
TCG  
SDT  
KW  
45.9  
82.9  
1.78  
43.7  
92.4  
2.02  
41.4  
102.  
2.29  
39.0  
111.  
2.60  
36.5  
121.  
2.93  
33.9  
131.  
3.29  
31.1  
140.  
3.67  
28.1  
150.  
4.07  
TCG  
SDT  
KW  
49.8  
84.8  
1.79  
47.4  
94.2  
2.04  
45.0  
104.  
2.31  
42.4  
113.  
2.61  
39.8  
123.  
2.95  
36.9  
132.  
3.31  
34.0  
142.  
3.70  
30.8  
151.  
4.12  
55  
See notes on page 21.  
—20—  
CONDENSER ONLY RATINGS* Continued  
CONDENSER ENTERING AIR TEMPERATURES °F  
SST  
°F  
55  
65  
75  
85  
95  
105  
115  
125  
533AN042-A  
TCG  
SDT  
KW  
36.9  
77.8  
1.90  
35.0  
87.5  
2.17  
33.0  
97.2  
2.46  
31.1  
107.  
2.80  
29.1  
117.  
3.17  
27.1  
127.  
3.59  
25.1  
136.  
4.07  
22.9  
146.  
4.60  
30  
35  
40  
45  
50  
55  
TCG  
SDT  
KW  
40.4  
79.3  
1.93  
38.3  
88.8  
2.19  
36.2  
98.5  
2.49  
34.1  
108.  
2.82  
32.0  
118.  
3.20  
29.9  
127.  
3.61  
27.6  
137.  
4.08  
25.2  
147.  
4.60  
TCG  
SDT  
KW  
44.2  
81.0  
1.97  
41.9  
90.4  
2.23  
39.7  
100.0  
2.53  
37.4  
110.  
2.86  
35.1  
119.  
3.23  
32.8  
129.  
3.64  
30.3  
138.  
4.11  
27.7  
148.  
4.63  
TCG  
SDT  
KW  
48.2  
82.8  
2.01  
45.7  
92.2  
2.27  
43.3  
102.  
2.57  
40.8  
111.  
2.90  
38.3  
121.  
3.27  
35.8  
130.  
3.68  
33.1  
140.  
4.14  
30.3  
149.  
4.66  
TCG  
SDT  
KW  
52.4  
84.9  
2.05  
49.7  
94.1  
2.31  
47.1  
103.  
2.61  
44.4  
113.  
2.95  
41.7  
122.  
3.32  
39.0  
132.  
3.73  
36.1  
141.  
4.19  
33.0  
150.  
4.70  
TCG  
SDT  
KW  
56.8  
87.0  
2.11  
54.0  
96.1  
2.37  
51.1  
105.  
2.66  
48.2  
115.  
3.00  
45.3  
124.  
3.37  
42.3  
133.  
3.78  
39.2  
142.  
4.24  
35.8  
152.  
4.75  
533AN048-A  
TCG  
SDT  
KW  
42.2  
76.9  
2.23  
40.0  
86.5  
2.53  
37.8  
96.3  
2.87  
35.6  
106.  
3.26  
33.4  
116.  
3.69  
31.1  
126.  
4.17  
28.7  
136.  
4.72  
26.2  
146.  
5.32  
30  
35  
40  
45  
50  
55  
TCG  
SDT  
KW  
46.3  
78.2  
2.26  
43.9  
87.7  
2.56  
41.5  
97.4  
2.90  
39.1  
107.  
3.28  
36.7  
117.  
3.70  
34.3  
127.  
4.18  
31.7  
137.  
4.72  
29.0  
146.  
5.32  
TCG  
SDT  
KW  
50.7  
79.8  
2.30  
48.1  
89.2  
2.59  
45.5  
98.7  
2.93  
42.9  
108.  
3.31  
40.3  
118.  
3.73  
37.6  
128.  
4.21  
34.8  
137.  
4.74  
31.8  
147.  
5.33  
TCG  
SDT  
KW  
55.2  
81.5  
2.35  
52.5  
90.8  
2.64  
49.7  
100.  
2.97  
46.9  
110.  
3.35  
44.0  
119.  
3.77  
41.1  
129.  
4.24  
38.1  
138.  
4.77  
34.9  
148.  
5.36  
TCG  
SDT  
KW  
60.1  
83.5  
2.40  
57.1  
92.6  
2.69  
54.1  
102.  
3.02  
51.1  
111.  
3.40  
48.0  
121.  
3.82  
44.9  
130.  
4.29  
41.6  
140.  
4.81  
38.1  
149.  
5.40  
TCG  
SDT  
KW  
65.1  
85.6  
2.45  
62.0  
94.6  
2.75  
58.8  
104.  
3.08  
55.5  
113.  
3.45  
52.2  
122.  
3.88  
48.8  
132.  
4.34  
45.2  
141.  
4.86  
41.4  
151.  
5.44  
533AN060-A  
TCG  
SDT  
KW  
53.6  
78.4  
2.84  
50.8  
87.9  
3.22  
48.1  
97.7  
3.64  
45.3  
108.  
4.12  
42.5  
117.  
4.65  
39.6  
127.  
5.24  
36.5  
137.  
5.86  
32.7  
146.  
6.46  
30  
35  
40  
45  
50  
55  
TCG  
SDT  
KW  
58.7  
79.9  
2.89  
55.7  
89.5  
3.26  
52.7  
99.2  
3.68  
49.7  
109.  
4.16  
46.7  
119.  
4.70  
43.6  
128.  
5.28  
40.3  
138.  
5.93  
36.5  
147.  
6.59  
TCG  
SDT  
KW  
64.0  
81.8  
2.94  
60.8  
91.2  
3.31  
57.6  
101.  
3.74  
54.3  
110.  
4.22  
51.0  
120.  
4.75  
47.7  
130.  
5.34  
44.2  
139.  
5.99  
40.3  
149.  
6.69  
TCG  
SDT  
KW  
69.7  
83.7  
3.00  
66.3  
93.1  
3.37  
62.8  
103.  
3.80  
59.2  
112.  
4.28  
55.6  
122.  
4.82  
52.0  
131.  
5.41  
48.2  
141.  
6.06  
44.0  
150.  
6.78  
TCG  
SDT  
KW  
75.6  
85.8  
3.06  
72.0  
95.1  
3.44  
68.2  
104.  
3.87  
64.4  
114.  
4.35  
60.5  
123.  
4.89  
56.5  
133.  
5.48  
52.4  
142.  
6.14  
47.9  
151.  
6.85  
TCG  
SDT  
KW  
81.9  
88.1  
3.14  
78.0  
97.3  
3.52  
74.0  
107.  
3.95  
69.9  
116.  
4.43  
65.6  
125.  
4.97  
61.2  
135.  
5.57  
56.8  
144.  
6.22  
51.9  
153.  
6.94  
* ARI listing applies only to systems shown in Ratings and Performance table.  
KW Total Power (Kw)  
SDT — Saturated Temperature Leaving Compressor (°F)  
SST — Saturated Temperature Entering Compressor (°F)  
TCG — Gross Cooling Capacity (1000 Btuh).  
—21—  
SYSTEM DESIGN SUMMARY  
1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.  
2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F (12.8°C).  
3. Maximum outdoor operating air temperature is 125°F (51.7°C).  
4. For reliable operation, unit should be level in all horizontal planes.  
5. Maximum elevation of indoor coil above or below base of outdoor unit is: Indoor coil above = 30 ft, indoor coil below = 30 ft.  
6. For interconnecting refrigerant tube lengths greater than 50 ft, consult the Residential Split-System Application Guideline and  
Service Manual for Air Conditioners and Heat Pumps using Puron® Refrigerant available from equipment distributor.  
7. If any refrigerant tubing is buried, provide a 6 in. vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36  
in. may be buried without further consideration. For buried lines longer than 3 ft, consult your local distributor.  
8. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector  
provided.  
9. Do not apply capillary tube indoor coils to these units.  
10. Factory-supplied filter drier must be installed.  
11. Do not deviate from factory specified TXV’s and Liquid Line Solenoids.  
—22—  
—23—  
Air-Cooled, Split-System  
Air Conditioner  
533A  
GUIDE SPECIFICATIONS  
2 to 5 Tons Nominal  
Fans  
GENERAL  
Condenser fan will be direct-drive propeller type, discharging air  
upward.  
Condenser fan motors will be totally enclosed, 1-phase type  
with class B insulation and permanently lubricated bearings.  
Shafts will be corrosion resistant.  
Fan blades will be statically and dynamically balanced.  
System Description  
Outdoor-mounted, air-cooled, split-system air conditioner unit  
suitable for ground or rooftop installation. Unit consists of a her-  
metic compressor, an air-cooled coil, propeller-type condenser  
fan, and a control box. Unit will discharge supply air upward as  
shown on contract drawings. Unit will be used in a refrigeration  
circuit to match up to a packaged fan coil or coil unit.  
Condenser fan openings will be equipped with PVC-coated  
steel wire safety guards.  
Quality Assurance  
Unit will be rated in accordance with the latest edition of ARI  
Standard 210.  
Unit will be certified for capacity and efficiency, and listed in the  
lastest ARI directory.  
Unit construction will comply with latest edition of ANSI/  
ASHRAE and with NEC.  
Compressor  
Compressor will be hermetically sealed.  
Compressor will be mounted on rubber vibration isolators.  
Condenser Coil  
Condenser coil will be air cooled.  
Coil will be constructed of aluminum fins mechanically bonded  
to copper tubes which are then cleaned, dehydrated, and  
sealed.  
Unit will be constructed in accordance with UL standards and  
will carry the UL label of approval. Unit will have c-UL approval.  
Unit cabinet will be capable of withstanding Federal Test Method  
Standard No. 141 (Method 6061) 500-hr salt spray test.  
Refrigeration Components  
Refrigeration circuit components will include liquid-line shutoff  
valve with sweat connections, vapor-line shutoff valve with  
sweat connections, system charge of Puron® (R-410A)  
refrigerant, and compressor oil.  
Air-cooled condenser coils will be leak tested at 250 psig and  
pressure tested at 450 psig.  
Unit constructed in ISO9001 approved facility.  
Delivery, Storage, and Handling  
Unit will be shipped as single package only and is stored and  
handled per unit manufacturer’s recommendations.  
Operating Characteristics  
The capacity of the unit will meet or exceed _____ Btuh at a  
suction temperature of _____ °F.The power consumption at full  
load will not exceed _____ kw.  
Combination of the unit and the evaporator or fan coil unit will  
have a total net cooling capacity of _____ Btuh or greater at  
conditions of _____ CFM entering air temperature at the  
evapo-rator at _____ °F wet bulb and _____ °F dry bulb, and  
air enter-ing the unit at _____ °F.  
Warranty (for inclusion by specifying engineer)  
U.S. and Canada only.  
PRODUCTS  
Equipment  
Factory assembled, single piece, air-cooled air conditioner unit.  
Contained within the unit enclosure is all factory wiring, piping,  
controls, compressor, refrigerant charge Puron® (R-410A), and  
special features required prior to field start-up.  
The system will have an SEER of _____ Btuh/watt or greater at  
DOE conditions.  
Electrical Requirements  
Refrigerant  
Nominal unit electrical characteristics will be _____ v, single  
phase, 60 hertz. The unit will be capable of satisfactory opera-  
tion within voltage limits of _____ v to _____ v.  
Refrigerant will be Puron HFC Refrigerant with zero ozone  
depletion potential. Puron is approved under the EPA’s  
Significant New Alternatives Program (SNAP).  
Unit electrical power will be single point connection.  
Control circuit will be 24v.  
Unit Cabinet  
Unit cabinet will be constructed of galvanized steel, bonderized,  
and coated with a powder coat paint.  
Special Features  
Fans  
Refer to section of this literature identifying accessories and  
descriptions for specific features and available enhancements.  
Condenser fan will be direct-drive propeller type, discharging air  
upward.  
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE  
UNIT MUST BE INSTALLED IN ACCORDANCE  
WITH INSTALLATION INSTRUCTIONS  
Cancels: NEW  
© 2000 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls, IN 46231  
—24—  
PRINTED IN U.S.A.  
Catalog No. 5253-300  
2-00  

Briggs Stratton THE POWER WITHIN 625 SERIES User Manual
Canon PIXMA MX410 Multifunction Printer 4788B018 User Manual
Carrier 014 080 User Manual
Friedrich Air Conditioner SL36 User Manual
Friedrich Air Conditioner SS14 User Manual
GE AZ75E09DAC User Manual
Goodman Mfg Co LP Air Conditioner RS6300011 User Manual
Haier 0010506358 User Manual
Hella Lights Automobile Accessories 3000 User Manual
HP Hewlett Packard LaserJet 3015 User Manual